Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 103 of 5194

Support move/rename of Attributes specified by path in Asset-based Calculation expressions

Currently, if an element or attribute is moved or renamed, any Asset-based Calculations in PI Vision with an expression that uses an AF path containing that element or attribute will return "No Data" as it is no longer be able to find that attribu...
Jason Lu about 1 month ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Allow bar graphs in trends

Add bar graphs as an option for trends
kimmyberly26 over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 2 No status

Use calculation as tags

It would be nice to be able to propagate calculations within PI by calling for other calculated variables within a new calculation. For example, where X, Y, and Z are PI Tags, I have a calculation A = X+Y. I would like to add a new calculation B...
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 No status

Display's Start/End Time in Vision Calculation

be able to have a Vision calc utilize the current start and end time of the display
Matt Voll over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 No status

Multistate does not recognize value in calculation (Text)

Allow multistate to recognize text
Guest 4 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Store bad quality from OPC server

Enhance the OPC DA Interface to store bad quality values from his OPC Server in PI, so that the values, timestamp and status from bad quality data are saved in PI.  Note: This was previously Enhancement 114636.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

OPC interface retries sending InstrumentTag/ItemID to OPC Server

The idea is to have PI Interface for OPC DA/HDA to be able to send again Instrument Tag/Item ID after a configurable time when OPC Server is not able to resolve it (AddItem failed). This would be a workaround for an OPC server issue and would help...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 3 No status

Use a calculation in another calculation

Currently, you cannot use a calculated variable in another calculation on PI Vision. This complicates calculations because all operations must be done under one calculation.
Navern Moodley over 1 year ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Calculated tags present value error

For calculated tags when being trended for more than ~12 hours time frame, the trend works fine except for the live present value, the calculation can be completely off. See attached screenshot for an example, where several tags are checked whethe...
AbdulRahman.Maskari 3 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Enhance the OPC DA interface to avoid mixing polled and advise tags on the same scan class

The interface does not log any informational messages about polled and advise tags getting mixed up on a scan class. Currently it would detect that polled tags are part of scan class 1 and reject it and print the following: E 13-Apr-16 17:26:18 ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status