Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 10

Add functionality to Pi Vision: Place to set thresholds that trigger email notifications

I have used other time series database and front ends that had the ability, while designing a screen, to also set thresholds on points and specify an email address that would get an alert email if the values were out of threshold. My company would...
dave sims about 1 year ago in AVEVA™ PI Vision™ / Notifications 0 No status

Link PI Vision error messages to source symbol on display to aid troubleshooting

When there is a dense display and an error is reported for a data source or symbol, it is difficult to find the symbol in error for further investigation. It would be useful if the error was somehow tied to the display element so that the symbol i...
Laurie Dieffenbach about 1 year ago in AVEVA™ PI Vision™ / Notifications 0 No status

Add Mod10 to Custom Data Type Manipulator for Modbus Interface

Please add support for SquareD Mod10 custom datatype to the Modbus Interface. Schneider Electric uses a custom datatype that uses four 16 bit registers. Each register represents an integer. Each integer is then multiplied by a factor and all resu...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Big Brother

Audible alarms that can be configured in the multistate menu w/ the ability to upload custom bytes. The ability to program a point to trigger an event that would wirelessly send alerts to a specified user or group (email or data text alert)
Guest over 3 years ago in AVEVA™ PI Vision™ / Notifications 0 No status

Test Modbus Serial interface with newer Operating Systems

Currently the Modbus Serial interface supports Windows 7 as the latest possible operating system. Please test the Modbus Serial interface version 4.0.7.61 with operating systems such as Windows 10 or 11. Or release a new Modbus Serial interface th...
Rachel Morgenroth about 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Provide support for Modbus function code 20

Provide support for Modbus function code 20
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Email Report out

auto generated emails at certain intervals (every 8 hours) that send out uptimes, case counts, selected data points which can be collected and sent to a distribution list.
Guest over 3 years ago in AVEVA™ PI Vision™ / Notifications 0 No status

A test Multi state button some of our displays have 100S would be nice to test the functionality even set limits so that they go off correct

Functionality Button even set to limits to see if the multistate on that page are functional
Guest over 3 years ago in AVEVA™ PI Vision™ / Notifications 0 No status

POINDexter app be modified such that addresses beyond 64000 can be used

POINDexter application be modified such that addresses beyond 64000 are able to be ‘tested’ / polled, rather than having to configure a tag to read those registers
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 3 No status

Interface for Modbus output to 4byte (32bit) registers

There are Modus supporting devices that feature 32bit single registers (e.g ROC800-Series). PI Interface for Modbus should be updated to have support to output to these 4byte (32bit) registers. Currently PI Interface for Modbus only has support f...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 2 No status