Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Batch Interfaces

Showing 55

Update EFGen Interface Health Tags To Allow For Better Status Monitoring

The current EFGen interface "Status" health tag displays a value of "Good" if it is connected to the data source but does not factor in if it is writing Event Frame data to PI. There is not currently a straightforward way to drive a PI Notificatio...
Guest over 2 years ago in PI Interfaces / Batch Interfaces 2 No status

PI EMDVB Interface should not use the STARTUP.dat to determine recovery start time when configured in Failover and running in RealTime mode.

Currently when the PI Interface for Emerson DeltaV Batch (EMDVB) is configured for failover and running in RealTime mode, the interface will use a recovery start time (RST) based on the last time the interface was active. This results in the inter...
Bethany Jewett 9 months ago in PI Interfaces / Batch Interfaces 2 Planned

Allow Tag Template Triggers to trigger on blank placeholders

Currently, Batch Interface Framework interfaces implement tag template triggers that can trigger whenever a placeholder has any value. These interfaces should also support triggering when a placeholder does not have a value. For example, our SISBa...
Guest over 2 years ago in PI Interfaces / Batch Interfaces 6 Planned

Batch Framework Interfaces - [TIME] placeholder should consider whether TS=LCL is configured

Batch Framework Interfaces - [TIME] and [TIMESTAMP] placeholders should consider whether TS=LCL is configured (meaning the interface is processing incoming events as Local Time). Currently, values of these placeholders always show up as GMT timest...
Guest over 2 years ago in PI Interfaces / Batch Interfaces 5 Planned

EFGEN - Allow Zeroth State strings to be used with Digital-type Active Points

When my EFGen Active Point tags have a type of digital, the interface should allow certain digital states to be designated as a Zeroth State.
Guest over 2 years ago in PI Interfaces / Batch Interfaces 1 No status

EFGEN - Allow for null/blank values to be Zeroth State for active point

When my EFGen Active Point tags have a null value, the interface should be able to designate this as a Zeroth State.
Guest over 2 years ago in PI Interfaces / Batch Interfaces 4 Tell us more

Link Referenced Elements from Unitprocedure to Procedure Event

When Eventframe Batches are created by a Batch Interface, the used Unit in the plant is created as Element in AF and linked to the Unitprocedure EventFrame. Unfortunately it is not linked to the parent Procedure Event, leaving the "referenced Elem...
juergen.b.schmidt over 2 years ago in PI Interfaces / Batch Interfaces 0 No status

Support Werum PAS|X 3.2 and PAS|X Data Access (PDA)

Werum has recently released the next version of their PAS|X Database, and it bolsters a new method of Data Access. OSIsoft will need to release an re-tooled version of their PI Interface for Werum PAS|X to support this latest Werum version and the...
Ellery Murdock over 2 years ago in PI Interfaces / Batch Interfaces 1 No status

efgen

Allow EFGen to use a Mix of PITAG + Text for the Creation of event frame names . Concatenate a Text + PITAG for example
valeman over 2 years ago in PI Interfaces / Batch Interfaces 4 No status

Allow diagnostic tags per failover node for batch interfaces

Batch interfaces should allow for diagnostic tags per failover node, just like UniInt based interfaces. Currently, there is no differentiation between the diagnostic tags for the primary failover node versus the backup failover node. The Location3...
Guest over 2 years ago in PI Interfaces / Batch Interfaces 0 No status