Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 15 of 5194

Update DataCollectorHealth and StorageHealth Asset type

EDS is pushing at least 2 Health assets (StorageHealth & DataCollectorHealth) with DeviceStatus stream but this stream is not inside the asset type as streamReference. So we are not able to use this stream to map into the Asset Status. Asset S...
Guest about 2 months ago in Edge Data Store / General 0 No status

Modify the Modbus Interface to accept 32-bit Unsigned Ints from the PLC

provide a data type to accept a 4 byte unsigned integer from the PLC.  At this point, it would be stored in a 64-bit float in PI DA.
Clint Ramsey over 3 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

Enable TLS Configuration

As a customer I want HTTP and HTTPS support for Edge DS so that I can configure the appropriate level of transport security for my deployment
Guest over 3 years ago in Edge Data Store / General 1 Declined

Support multiple Modbus devices on the same machine

Add support for multiple Modbus devices (using the same IP address but different port numbers) on the same machine. For example, the interface could allow the user to configure something like this: /dn= xxx.xx.xxx.xx:43120,/cn=1,/polldelay=0,/to...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

Provide GUI for Configuration

Edge Data Store would require a GUI for configuration and health status to work more efficiently to set it up with too many efforts. The GUI should allow to set up the connection to the Data sources of the included PI Adapters, provide OPC UA brow...
Guest almost 2 years ago in Edge Data Store / General 0 No status

Allow EdgeCmd to set null or empty string parameter values

As per KB000042993, setting parameters with EdgeCmd that are <null> or "" (empty string) is not possible. Instead the JSON configuration file must be created and used in place. It would be more intuitive if executing commands such as: edgecm...
Mike Horrocks over 1 year ago in Edge Data Store / General 1 No status

Add Mod10 to Custom Data Type Manipulator for Modbus Interface

Please add support for SquareD Mod10 custom datatype to the Modbus Interface. Schneider Electric uses a custom datatype that uses four 16 bit registers. Each register represents an integer. Each integer is then multiplied by a factor and all resu...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

EDS: security/authentication mechanism

Customer wants to deploy EDS at machine level to collect data from PLCs which are directly connected to the machine which would imply a proper security / authentication mechanism for EDS
Guest over 3 years ago in Edge Data Store / General 1 Tell us more

Test Modbus Serial interface with newer Operating Systems

Currently the Modbus Serial interface supports Windows 7 as the latest possible operating system. Please test the Modbus Serial interface version 4.0.7.61 with operating systems such as Windows 10 or 11. Or release a new Modbus Serial interface th...
Rachel Morgenroth about 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Provide support for Modbus function code 20

Provide support for Modbus function code 20
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status