To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 49 of 5213

Update DataCollectorHealth and StorageHealth Asset type

EDS is pushing at least 2 Health assets (StorageHealth & DataCollectorHealth) with DeviceStatus stream but this stream is not inside the asset type as streamReference. So we are not able to use this stream to map into the Asset Status. Asset S...
Guest about 1 month ago in Edge Data Store / General 0 No status

Sum-Difference performance equation/Analytics Function

Develop a new calculation function, performance equation, analytics function, etc for calculating a summation of differences for all of the archive events for a PI tag across a given range. For example, looking for something that can take a given ...
ejr5067 5 months ago in AVEVA™ PI System Access (PSA) / General 0 No status

Allow EdgeCmd to set null or empty string parameter values

As per KB000042993, setting parameters with EdgeCmd that are <null> or "" (empty string) is not possible. Instead the JSON configuration file must be created and used in place. It would be more intuitive if executing commands such as: edgecm...
Mike Horrocks over 1 year ago in Edge Data Store / General 1 No status

Add a new diagnostic: the IO rate in bytes or megabytes

The current IO rate diagnostic is helpful, but it only shows events per second. For sites who need to manage their bandwidth and make decisions about how much to buy and support from remote sites, it's very important to be able to monitor exactly ...
Daniel Lopez over 1 year ago in Edge Data Store / Egress 0 No status

Conditional Data Egress for Edge Data Store

Scenario: In a remote monitoring scenario, Edge Data Store is collecting data through OPC UA or ModbusTCP with a certain sampling rate (assumingly 1s). For normal operations, EDS shall egress only an aggregated one minute value of all analogue str...
Guest almost 2 years ago in Edge Data Store / Egress 0 No status

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...
Hans-Otto Weinhold almost 2 years ago in Edge Data Store / Historian 0 No status

Provide GUI for Configuration

Edge Data Store would require a GUI for configuration and health status to work more efficiently to set it up with too many efforts. The GUI should allow to set up the connection to the Data sources of the included PI Adapters, provide OPC UA brow...
Guest almost 2 years ago in Edge Data Store / General 0 No status

Align all developer tools to have access to the same data

The different PI developer tools do not have the ability to retrieve the same data. For example, a user cannot retrieve PI connection statistics from the AFSDK. That is only accessible via PowerShell (Get-PIConnectionStatistics). In C# or PI WebAP...
GaryYegiazaryan almost 2 years ago in AVEVA™ PI System Access (PSA) / General 2 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 2 years ago in Edge Data Store / Ingress 0 Planned

Search ability in AF Client on more than just element.

It would be nice to be able to search anything when it comes to AF Client. If I wanted to search and find reference to all Motor Speed Attributes.If I wanted to search on where a tag 'Sinusoid' for example was referenced in:Attributes, Analysis', ...
BrentWebsterADM about 2 years ago in AVEVA™ PI System Access (PSA) / General 0 No status