Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA PI OPC UA Server

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 7 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP Future consideration

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA Future consideration

The Adapter framework needs to be able to perform scaling on raw data

Many users want to use Adapters for the nre abilities they offer versus Interfaces: Support for containers, Linux, edge deployment, new failover and fault tolerance, integration with CONNECT Data Services, etc. HOWEVER, many sites use Interfaces t...
Daniel Lopez 9 months ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 Future consideration

EdgeCmd "add" data selection with CSV

At the moment the EdgeCmd data selection with a file path is limited to get and set. This means that to perform an update the data selection needs to be exported, modified, and the imported. It would be a great time saver to be able to provide a s...
Mike Horrocks 9 months ago in AVEVA™ Adapters / General Future consideration

Bitmask Functionality in AVEVA PI OPC UA Adapter

During the migration from the PI OPC DA Interface to the AVEVA PI OPC UA Adapter, we noticed that the ability to apply bitmasks to incoming values is no longer supported. This functionality is critical in many existing implementations, especially ...
Dennis Fendel 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA Future consideration

Custom HTTP header

add functionality so will bepossible to configure the PI Adapter for OPC UA to include a custom HTTP header when authenticating requests to the PI Web API endpoint The request for this feature recently came up in a support case for PPC (Dev CR: CR...
Dimitrios Pilos 10 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA Future consideration

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
sahilp about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA Future consideration

Supress PI-APS messages for Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table

Seeing "information" messages in PI-SDK related to "Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table" which is irrelevant to see in the logs. If one source instance sending to multiple destination instances...
AshwinC almost 3 years ago in PI Interfaces / PI to PI Interface Future consideration

PI OPC Tools Upgraded for Packet Integrity Support

Please update the PI OPC Tools to support Packet Integrity authentication. The tools are useful and I would like to see them maintained and support with the latest requirements from Microsoft patches.
Kimlin Pen almost 3 years ago in PI Interfaces / General Future consideration

ICU Service Account format

ICU only accepts domain\account format for the service account the interface is running under. A newer format account@FQDN is now used for new Windows server AD. This format should also be allowed. The current workaround is to change the log on ac...
BillBPA almost 3 years ago in PI Interfaces / Installation Future consideration