Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 350

OPC UA server failover based on watchdog tag

Gen2 PI Connector for OPC UA support OPC UA server level failover. How the Connector determine when to failover to the other OPC UA server: As per 6.6.2.4.2 ServiceLevel , this is used by the client to determine whether to connect/disconnect fro...
Ee Sheing Lee 19 days ago in PI Connectors / PI Connector for OPC UA 1 No status
118 VOTE

PI OPC UA Connector Array support

Add reading capability for OPC UA Arrays. Currently items with “ValueRank“ = 1 are ignored.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 11 No status
108 VOTE

Support HTTP Token Authentication to a REST Endpoint

The REST endpoint from which I want to pull data requires token authentication. I would like the UFL Connector to be able to obtain the token given the username and password I enter on the Admin page.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 6 No status

PI OPC UA Connector to write Bad Input/Configure

PI OPC UA Connector to write Bad Input/Configure when the respective NodeId is no longer available in OPC UA Server.
Fnu Safdar 16 days ago in PI Connectors / PI Connector for OPC UA 0 No status

Configurable input REST data queue file size for PI Connector for UFL

We're working with a large AMI customer, using the PI Connector for UFL as a REST server endpoint to receive meter data. However, during large interrogations, the amount of messages received can be faster than UFL can process, leading to overflowi...
Kendell Jillson about 1 month ago in PI Connectors / PI Connector for UFL 0 No status

Control which PI/AF servers each data source sends data to.

Right now, for one instance of the connector, all configured data sources will send data to all configured PI Data Archives and PI AF Servers. It is all or nothing. Due to the fact that you cannot have multiple instances of the same connector on a...
Guest over 3 years ago in PI Connectors / General 0 No status

Setting to allow the omission of error strings in Calculated or Filtered Results

Give the customers either an option or an application setting that allow them to omit error strings from function output. This would allow them to more easily chart results. Some examples of current strings that cause charting problems include, th...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Functions 1 No status

Support for UOM conversions

Being able to specify a UOM that is not the default UOM and having the value returned converted in all functions Note: This was previously Enhancement 25182OSI8
Guest over 3 years ago in AVEVA™ PI DataLink™ / Functions 2 No status

Ability for PI Connectors to create future data point

Add the ability for PI Connectors to create future data point. This is especially useful for the PI Connector for UFL. The current workaround is to manually create the point as a StoredValues=FutureData.
Gabriel Verreault over 3 years ago in PI Connectors / General 0 No status

Enable setting tag attributes in UFL Connector

UFL Connector should have ways to set tag attributes. There should be way to set the default compression and exception settings and also other tag attributes like point and data security.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 3 No status