To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 28 of 5194

Wonderware connector to store Bad/Questionable data from the WW Historian and flag as System Digital State (for example Bad Input, Bad etc) in the same Value PI Tag

As of the connector version 1.6.9.14, we can choose to store the Quality from the Historian in a separate Quality PI Tag (on top of the value PI Tag). Bad quality value is not being stored nor flagged in the Value PI Tag but this can be captured i...
Ee Sheing Lee over 2 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Migration from interface to connector

Would like a way to migrate from interface to connector as easily as possible.
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 2 No status

Add failover capability for the BACnet Connector.

Failover similar to the UFO available for UNIint interfaces.  Warm failover would be sufficient, although I'm sure there are some who would like cold and hot as well.
Chris Wozniak over 3 years ago in PI Connectors / PI Connector for BACnet 1 No status

PI Connector for Wonderware Historian should be configurable to use 'FULL' mode query

The connectors should have a standard behavior. We believe the Wonderware connector should be collecting data in the same way as the Cygnet connector by getting all the data stored in the source historian irrespective of the value change. Currentl...
Guest over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

BACnet SC/SuperConnect Support

Support for the BACnet SC/SuperConnect protocol for the PI Adapter, PI Connector, or PI Interface.
Connor Hawkins almost 2 years ago in PI Connectors / PI Connector for BACnet 4 No status

trend log objects (BACnet object type 20) available from the connector

BACnet trendlog object present the opportunity to buffer at the edge where the data is collected and to gracefully recover from comms outages if data collection has been impacted. I would suspect the trendlog object could be handled similarly to ...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Wonderware Historian Connector should store some metadata in PI tag attributes

The Description, Maximum EU, Minimum EU, Engineering Units, etc. that are stored in the Wonderware historian should be stored in the PI tags' attributes as well as the Wonderware AF structure.
Guest over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 1 No status

Make the connector a BACnet Device (get a BTL listing)

Some devices can only send COV notifications to other BACnet devices. Since the Connector is not a device and does not respond to who-is messages (and does not listen on port 47808), the connector is unable to utilize COV subscriptions for these d...
Paul Kim over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Suppress the creation of "Status Flag" PI Points

The end-user would like to suppress the creation of the "Status Flag" PI Points, as they wish to keep their point count to a minimum due to the license-enforced point limit.
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Validate credentials before running connector

Need a way to easily confirm that the credentials are correct before I try and run the connector.  Would like to see any errors surfaced via the web page so I can troubleshoot.