Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

My ideas: AVEVA Adapter for OPC UA

Tag path in PI Point attribute

As a PI administrator or super user, I would like the AVEVA Adapter for OPC UA to capture the tag path (eg. Plant|Area|Unit|SubUnit|Equipment|Sensor) from the OPC UA model into an attribute of the PI Point, eg instrumenttag. This would make it eas...
Clement Dekeyser about 2 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA No status

OPC UA Adapter should validate/disallow unsupported StreamId characters (or warn) instead of URL-encoding and publishing invalid streams to CONNECT

When the OPC UA Adapter discovers tags/names containing unsupported characters (e.g., [ / ]), it publishes StreamIds into AVEVA CONNECT where the characters appear URL-encoded (e.g., %5B / %5D). These streams then fail to receive values and cannot...
David Scott about 2 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA No status

PI Adapter for OPC UA to support X509 client authentication

Add support for X509 client authentication to OPC UA servers
Guest 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA No status

Add a parameter for the Adapter to increase the Keep-Alive wait time

Currently, there is no parameter on the Adapter side to increase the Keep-Alive wait time. It would be best to add parameter for the Adapter to increase the Keep-Alive wait time.
Alexa Derago 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA No status

Enable AVEVA Adapter for OPC UA to detect unchanged source values beyond a configured interval and continue sending the last known value with refreshed timestamps until a new source event is received

This enhancement is required so the AVEVA Adapter for OPC UA can functionally match ABB 800xA / Vtrin RTDB historical behavior while preserving existing PI System and Asset Framework functionality. The customer would like this capability implement...
Claudia Sischin 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA No status

An option to store symmetric keys in a file - OPC UA

It would be helpful to be able to read network trace between OPC UA Server and Adapter even if communication is encrypted. This possibility is described here https://www.unified-automation.com/news/news-details/analyzing-encrypted-opc-ua-traffic-w...
Mateusz Dura 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA No status

PI Tag Mapping configuration in the background of PI OPC UA Adapter to use Point ID

The CSV / JSON file in the background will have the mapping between the OPC UA Server tag against its' respective PI Tag Name. In such case, if we need to change the tag name after sometime, then which results in multiple process like stop the Ada...
Navaneethakrishnan 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA No status

PI Adapters should handle good NULL Values like PI Connectors and submit to the archive

A PI Connector reading a Null value in good quality send it to the Archive A PI Adapter skip the value, this gives in the archive a wrong picture. please enable the PI Adapter to submit also Null values with good quality to the archive like PI Con...
Markus Rombach 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA No status

Enable AVEVA Adapter for OPC UA to work with OPC UA Servers that only allow Dynamic Addressing and Virtual Browsing

Some OPC UA Servers have the concept of Dynamic Namespace Addressing and Virtual Browsing. The UA Nodes do not exist in the OPC UA Address Space. Nodeids are created\added to the Address Space only when a Client makes a request for the NodeIds thr...
Vaskar Dahal 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA No status

Automated discovery on a schedule

Enable Regular Discovery: While not continuous by default, discovery can be scripted or scheduled to run periodically for dynamic environments include this as a feature, so that automatic discovery and automatic addition of new discoveries can be ...
Nick Ciampa 10 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA No status