To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 295

PI Adapters should handle good NULL Values like PI Connectors and submit to the archive

A PI Connector reading a Null value in good quality send it to the Archive A PI Adapter skip the value, this gives in the archive a wrong picture. please enable the PI Adapter to submit also Null values with good quality to the archive like PI Con...
Markus Rombach 12 days ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Admin Option to block check-in of linking an Analysis output to a Static Attribute

It is easy for AF Users to create a new attribute with Data Reference = None (aka Static Attribute) but then assign an analysis to update its value later. When this happens, all updates to the attribute are stored in table FindChanges_AT which can...
John Alessio 25 days ago in AVEVA™ PI Server / Analytics & Calculations 1 No status
407 VOTE

Extensible analytics

As a process engineer I would like to be able to integrate complex specific calculations, such as from a 3rd party analytics engine, so that I can use the Asset Analytics and its context with all the available data and scheduling to run those with...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 48 No status
233 VOTE

Event Frame End Trigger Time True Functionality

As a user of event frames, I would like the ability to be able to set a time true condition for the end trigger of an event frame analysis, similar to how this functionality is available for the start trigger
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 9 No status
207 VOTE

Automatic Recalculation of Event Frame in PI Analysis

As a user, I would like to have the option to automatic recalculation of event frame for out-of-order input events in AF analysis. The option is available for expression analysis in PI Analysis  2017 R2 but not for event frame generation anal...
Willy Seah Wei Liat over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 25 No status
193 VOTE

Filter expression for inputs to a Rollup

As a user configuring a Rollup analysis, I want to be able to apply a filter expression on the inputs so that the Rollup only includes inputs that satisfy a condition. Note: This was previously Enhancement 114349.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 14 No status

Enable AVEVA Adapter for OPC UA to work with OPC UA Servers that only allow Dynamic Addressing and Virtual Browsing

Some OPC UA Servers have the concept of Dynamic Namespace Addressing and Virtual Browsing. The UA Nodes do not exist in the OPC UA Address Space. Nodeids are created\added to the Address Space only when a Client makes a request for the NodeIds thr...
Vaskar Dahal 23 days ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status
105 VOTE

Support Analysis Data Reference Step Functionality

Use case: User wants to trend Analysis Data Reference in client tools (Processbook, Coresight). User doesn’t want to create a PI tag for this output. Currently, the AnalysisDR ignores step, even if it’s input attributes are step.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 9 No status
104 VOTE

Be able to disable auto backfilling on a per analysis basis

Currently in the analysis service configuration there is a parameter called “AutoBackfillingEnabled” which affects the analysis calculations in a global basis. It would be great if it were possible to disable the auto backfilling to individual cal...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 8 No status

Start/stop components to be retained on restart

Currently it is possible to stop a component for a running adapter. However, if the adapter is restarted the component will automatically start up. It would allow for extra control during commissioning, downtime, incidents, etc. to be able to disa...