AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

My ideas

Showing 40 of 5213

Update DataCollectorHealth and StorageHealth Asset type

EDS is pushing at least 2 Health assets (StorageHealth & DataCollectorHealth) with DeviceStatus stream but this stream is not inside the asset type as streamReference. So we are not able to use this stream to map into the Asset Status. Asset S...
Guest about 1 month ago in Edge Data Store / General 0 No status

Optimize Bulk Asset Stream Reference Subscriptions for Broker Signups

Currently, when creating or managing a signup in the broker based on an asset search, we must iterate through each returned asset to retrieve its stream references. This process results in thousands of individual API calls, significantly impacting...
Ronald_Bechaalany about 2 months ago in Developer Resources / AVEVA™ Data Hub API 0 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Allow EdgeCmd to set null or empty string parameter values

As per KB000042993, setting parameters with EdgeCmd that are <null> or "" (empty string) is not possible. Instead the JSON configuration file must be created and used in place. It would be more intuitive if executing commands such as: edgecm...
Mike Horrocks over 1 year ago in Edge Data Store / General 1 No status

Add a new diagnostic: the IO rate in bytes or megabytes

The current IO rate diagnostic is helpful, but it only shows events per second. For sites who need to manage their bandwidth and make decisions about how much to buy and support from remote sites, it's very important to be able to monitor exactly ...
Daniel Lopez over 1 year ago in Edge Data Store / Egress 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Conditional Data Egress for Edge Data Store

Scenario: In a remote monitoring scenario, Edge Data Store is collecting data through OPC UA or ModbusTCP with a certain sampling rate (assumingly 1s). For normal operations, EDS shall egress only an aggregated one minute value of all analogue str...
Guest almost 2 years ago in Edge Data Store / Egress 0 No status

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...
Hans-Otto Weinhold almost 2 years ago in Edge Data Store / Historian 0 No status

Provide GUI for Configuration

Edge Data Store would require a GUI for configuration and health status to work more efficiently to set it up with too many efforts. The GUI should allow to set up the connection to the Data sources of the included PI Adapters, provide OPC UA brow...
Guest almost 2 years ago in Edge Data Store / General 0 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status