To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

My ideas

Showing 53 of 5213

Optimize Bulk Asset Stream Reference Subscriptions for Broker Signups

Currently, when creating or managing a signup in the broker based on an asset search, we must iterate through each returned asset to retrieve its stream references. This process results in thousands of individual API calls, significantly impacting...
Ronald_Bechaalany about 2 months ago in Developer Resources / AVEVA™ Data Hub API 0 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

A Bulk Call for Last Values

A customer asks for a way to retrieve the last values of a group of streams in a single call.
Victor Zhang about 2 years ago in Developer Resources / AVEVA™ Data Hub API 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Accept HEX numbers for Register offsets in data selection

Most modbus equipment providers provide information using registers in Hex format i.e. 0x0000 ~ 0xFFFF. It would be nice if the offset could accept this to avoid error in conversions HEX to DEC. Would make things alot more seamless/easier.
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Allow PICC to use the PI Server name with the Point Id# to stop conflicting data streams when multiple PI servers are combined in a PIAF structure

Currently only the point id is used in PICC to track data streams. This is not an issue a single PI server data source. With PIAF multiple PI servers are used to collect data stream. We are now seeing data streams being overwritten by multiple PI ...
TimS about 3 years ago in PI Cloud Connect / General 0 No status

Create an API that helps deliver an appropriate amount of data to the user or application

As a data scientist or UI user, I don't know how much data I'm requesting when I ask for a sequence of data. However, I can provide some boundary conditions to help scope the request SO THAT OCS can deliver an appropriate level of detail for my us...
Guest over 3 years ago in Developer Resources / AVEVA™ Data Hub API 0 No status