To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 15 of 5194

Modify the Modbus Interface to accept 32-bit Unsigned Ints from the PLC

provide a data type to accept a 4 byte unsigned integer from the PLC.  At this point, it would be stored in a 64-bit float in PI DA.
Clint Ramsey over 3 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

Publish PI Symbol “String Values Plot symbol” on GitHub

We would like to get the PI Vision symbol "String Values Plot Symbol", extracted from the 2018 PI World Lab attached, not available anymore on GitHub. The idea is to have a symbol that represents the different states of a machine during some peri...
psantosmoreno over 3 years ago in Developer Resources / Sample Requests 0 No status

Publish a sample of code to do an histogram

Publish a sample of code to do an histogram with PiVision extensibility. There is already a sample using a unique value (arrow) but there should be an exemple for charts to help people customise their experience further.
Guest over 3 years ago in Developer Resources / Sample Requests 1 No status

Support multiple Modbus devices on the same machine

Add support for multiple Modbus devices (using the same IP address but different port numbers) on the same machine. For example, the interface could allow the user to configure something like this: /dn= xxx.xx.xxx.xx:43120,/cn=1,/polldelay=0,/to...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

Add Mod10 to Custom Data Type Manipulator for Modbus Interface

Please add support for SquareD Mod10 custom datatype to the Modbus Interface. Schneider Electric uses a custom datatype that uses four 16 bit registers. Each register represents an integer. Each integer is then multiplied by a factor and all resu...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

PI Vision Extensibility - Sound on state change

A functionality that currently exists in Processbook is to play a sound file using the VBA script (driven for example, buy a PI Point changing state). I would like to replicate this functionality in PI Vision
Guest over 3 years ago in Developer Resources / Sample Requests 0 No status

OMF sample in node-red

I would like a sample that shows creating OMF data in Node-RED
Guest over 3 years ago in Developer Resources / Sample Requests 0 No status

Test Modbus Serial interface with newer Operating Systems

Currently the Modbus Serial interface supports Windows 7 as the latest possible operating system. Please test the Modbus Serial interface version 4.0.7.61 with operating systems such as Windows 10 or 11. Or release a new Modbus Serial interface th...
Rachel Morgenroth about 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Provide support for Modbus function code 20

Provide support for Modbus function code 20
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

POINDexter app be modified such that addresses beyond 64000 can be used