To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 47

Modify the Modbus Interface to accept 32-bit Unsigned Ints from the PLC

provide a data type to accept a 4 byte unsigned integer from the PLC.  At this point, it would be stored in a 64-bit float in PI DA.
Clint Ramsey over 1 year ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

Support multiple Modbus devices on the same machine

Add support for multiple Modbus devices (using the same IP address but different port numbers) on the same machine. For example, the interface could allow the user to configure something like this: /dn= xxx.xx.xxx.xx:43120,/cn=1,/polldelay=0,/to...
Guest over 1 year ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

and operator

Add a function that can be used in the UFL Configuration File to perform bitwise operations. For example, a function similar to the AND operator in Performance Equations and Asset Analytics.
Guest over 1 year ago in PI Interfaces / PI Interface for UFL 1 Declined

PI OPCtoCSV tool to continue running and skip branches in error

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. When the tool is run into error with certain branches, the tool will stop and disconnected from the OPC server/tunneller. For example: “GetItemProperti...
Ee Sheing Lee over 1 year ago in PI Interfaces / General 1 Declined

Support Automatic Failover for PI UFL

Currently UFL only supports two independent instances for redundancy purposes.
Guest over 1 year ago in PI Interfaces / PI Interface for UFL 0 Declined

Allow PItoPI APS connector to sync "Point Type" changes

Currently (as of PI to PI Interface AutoPointSync Connector Version 1.5.0.7), it's not possible to sync changes to "Point type". (See pg 5 of user manual). Please make this possible in a future release.
Guest over 1 year ago in PI Interfaces / General 0 Declined

Enhance element creation to use user defined element templates

The interface can automatically create an element at each level of event frames, but the elements do not derive from a template and there is no way to specify any attributes on the element. The enhancement request is to create elements that are ba...
Guest over 1 year ago in PI Interfaces / Batch Interfaces 0 Declined

PI EMDVB Interface - Rename Parsed Files

PI EMDVB Interface - Rename Parsed Files.  Files that get renamed to .999 is no longer available with PI EMDVB.  This file renaming feature was very useful from a system maintenance perspective.  We would easily remove .999 from the active EVT fol...
Guest over 1 year ago in PI Interfaces / Batch Interfaces 0 Declined

Ability to monitor changes in interface configuration.

Need to know when the interface configuration was edited and which parameter was changed.
Qasim Asghar 7 months ago in PI Interfaces / General 0 Declined

Delete mode in Wonderware InBatch interface

When run in delete mode for WWInBatch interface, it uses the data source as the system of record--any open batch in SQL will be deleted. However, as abandoned or done  batches are open in WonderWare but closed in PI, the interface may delete batch...
Willy Seah Wei Liat over 1 year ago in PI Interfaces / Batch Interfaces 0 Declined