To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 63

Support dynamic indexes from Linux devices for PI Interface for SNMP

When the interface machine needs to be restarted for any reason, the connection to the source (when a Linux device) is lost because Linux uses dynamic indexes and the Interface does not have a way to manage that. Tags need to be reconfigured every...
Laurie Dieffenbach 18 days ago in PI Interfaces / Other Interfaces 1 Declined

PI Interface for Bacnet: Adding support of ObjectType=Timer

We would like to get a value of ObjectType=Timer object in PI BACNet interface but it is not supported. One of the Timer object contains important time setting and we need to check it every month. However currently we need to check the value from ...
Kenji Hashimoto 23 days ago in PI Interfaces / Other Interfaces 1 Declined

Modify the Modbus Interface to accept 32-bit Unsigned Ints from the PLC

provide a data type to accept a 4 byte unsigned integer from the PLC.  At this point, it would be stored in a 64-bit float in PI DA.
Clint Ramsey almost 2 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

RDBMS Interface version that support the failovertime > 20s (UFO_Interval)

If you have a query that lasts longer than 40s and a phase2 failover configuration is used. The interfaces switch constantly from primary to secondary and viceversa. With the parameter "UFO interval" you can control this behavior. However, this pa...
MiguelPalomo almost 2 years ago in PI Interfaces / PI Interface for RDBMS 1 Declined

Support multiple Modbus devices on the same machine

Add support for multiple Modbus devices (using the same IP address but different port numbers) on the same machine. For example, the interface could allow the user to configure something like this: /dn= xxx.xx.xxx.xx:43120,/cn=1,/polldelay=0,/to...
Guest almost 2 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

and operator

Add a function that can be used in the UFL Configuration File to perform bitwise operations. For example, a function similar to the AND operator in Performance Equations and Asset Analytics.
Guest almost 2 years ago in PI Interfaces / PI Interface for UFL 1 Declined

Allow PItoPI APS connector to sync "Point Type" changes

Currently (as of PI to PI Interface AutoPointSync Connector Version 1.5.0.7), it's not possible to sync changes to "Point type". (See pg 5 of user manual). Please make this possible in a future release.
Guest almost 2 years ago in PI Interfaces / General 0 Declined

PI OPCtoCSV tool to continue running and skip branches in error

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. When the tool is run into error with certain branches, the tool will stop and disconnected from the OPC server/tunneller. For example: “GetItemProperti...
Ee Sheing Lee almost 2 years ago in PI Interfaces / General 1 Declined

Support Automatic Failover for PI UFL

Currently UFL only supports two independent instances for redundancy purposes.
Guest almost 2 years ago in PI Interfaces / PI Interface for UFL 0 Declined

Allow using SQL as a data source for FactoryTalk Batch

Rockwell FactoryTalk Batch v12.01 allows to output batch data to a SQL database as well as EVT files. Just like with EMDVB, the PI Interface for FTBatch should be able to use both data sources.
Alan Izar almost 2 years ago in PI Interfaces / Batch Interfaces 1 Declined