To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 127 of 5194

Allow user to set defaults for trends (colors of traces and background, number of ad hocs per trend, font size, similar to Processbook

This would allow the user a consistent view when opening trends as well as being able to set font size to be able to view the trend on various size monitors. Also, having the ability to set the number of ad hocs per trend like Processbook allowed ...
Shane Loehr about 2 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

Interface should reload performance counters after failover and keep track of them.

The interface should be designed to reload counters both at startup and when becoming the active interface after a failover. The interface should realize the counter is not available and periodically attempt to reload (ideally with a message to th...
Nicolas Capera Choconta over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

plz display the limits for asset comparison tables (Ad Hoc trending)

We have AF configured with multistate limits . This is very useful for adhoc analysis, because when we have a gauge chart in PIvision, adding it to the adhoc will trend both the actual value + the limits (i.e. limits such as HighHigh, High, Low, L...
AlejandroGL over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 1 No status

Show the Tag and PI Interface for an Attribute on a Display

Have a way to see the source PI interface somewhere on the display for monitoring and troubleshooting reasons. For example, if there's a flat line on the data.
Guest over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 Declined

Ability to show values near the pen lines rather than at the top of the trend (adhoc trending)

Ability to show values in an adhoc trend at the pen line rather than at the top. When comparing a large number of data items it is hard to distinguish the different values when they are all listed at the top of the trend
Guest over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

Improve ad-hoc calc tool

The recently added "calculations" could be very useful but in reality is of limited use because it bogs down the system and cannot be used over long periods of time (years). PHD / Uniformance, the tool we used before PI Vision, was easily able to ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status