To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 162 of 5192

Synchronize times on symbols, or not, with one step

When analyzing an issue, it is helpful to be quickly determine whether all the symbols on a display are using the same time range or not.  For example, one might want to compare values from upstream in the process to values farther downstream...
Guest over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

PI Vision URL Parameter for Ad-Hoc Displays to Show Periodic Interpolated Values

For ad-hoc displays, can we add a URL parameter to indicate a sampling / interpolation duration? We can put in start time and end time, but instead of getting the raw value is it possible to, for instance, request interpolated results at 1h time b...
Robert Reed over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

Need to be able to trend calculations or constants (limits)

I cannot reproduce this in PI Vision. I need to be able to add limit lines to trends. I previously did this by adding a PI calculation set at a constant value.
Guest over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 2 No status

Enable clipboard capture of cursor values

When I drop a cursor on the trend symbol, I can see the current value at the cursor's timestamp of all trend traces in a small side pop-up. I would like to be able to copy to clipboard these so I can use them in an email, or in another report. N...
Guest over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

Better feedback for errors in ad hoc calculations

Direct quote from customer, "The suggestion is for the ad-hoc calculation parser to highlight where any parsing errors are. Currently it just says there is an error and it often takes a while to find it." Currently when clicking the Preview butto...
Brent Bregenzer over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

AF-to-CONNECT should capture Categories

It would be helpful if the PI to CONNECT Agent could read the Category from an AF Attribute and write meta data to the Stream associated with the Category. This would be used to identify which of the AF Attributes are to be included in a DataView ...
Guest over 3 years ago in PI to CONNECT 0 No status

AF Attribute not recongized in CONNECT transfer configuration if PI point data reference config string contains a datatype

We encountered an issue with PI to CONNECT (using current version of the Agent 2.2) not recognizing AF Attributes with PI Point Data References which have the pointtype in the data reference configuration. So that means if there is a config string...
Julian Weber over 2 years ago in PI to CONNECT / General 0 No status

Use PI Server Alternate Display Name in stream naming pattern

The PI Server Alternate Display Name is only used to build the stream IDs. It would be better to use it in the stream naming pattern as well.
Clement Dekeyser almost 3 years ago in PI to CONNECT / General 0 No status

Seamless change of PI Server Alternate Display Name

When the PI Server Alternate Display Name is modified, new streams are created to receive live data while historical data remains only in the existing streams. It would be better to automate: the deletion of existing streams the backfilling of new...
Clement Dekeyser almost 3 years ago in PI to CONNECT / General 0 No status

Trend: show cursor values when trend is located at the very top of the screen

Currently, whenever a trend is located at the very top of the screen, the cursor values & dates would not be visible, as they would be behind the ribbon above it. See attached screenshot. Please fix this by making the cursor value & time v...
AbdulRahman.Maskari about 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status