To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Prevent AutoPointSync from using SYSTEM Digital state set

AutoPointSync automatically assigns the SYSTEM Digital State set to Digital tags, this should be prevented as it can create confusion and issues down the road.
Guest over 1 year ago in PI Interfaces / General 0 No status

Enhance AutoPoint Sync APS to sychronize point sets larger than 100,000 points

https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01426 PI AutoPoint Sync is a 32-bit application an can only synchronize 100,000 points in a point source. Recommend to develop the application to use a 64-bit architecture to h...
Luke Peters almost 4 years ago in PI Interfaces / Other Interfaces 0 No status

Find data and events when an asset was running

For assets that aren't always running, it can be hard to find events (EFs) that have happened back in history. Provide a way to more easily find these events and/or only show data on trends while the asset was running. (hide time periods).
Guest almost 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

PIVision: Long/Lat control to drag Long/Lat attributes onto

Ability to click on a long/lat attribution your display and it opens up google maps and shows you how to get to your troubled asset. Might end up being a new control that you can place on the desktop and drag the long/lat attribute(s) on to it.
Guest almost 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 Declined

PI Vision URL Parameter for Ad-Hoc Displays to Show Periodic Interpolated Values

For ad-hoc displays, can we add a URL parameter to indicate a sampling / interpolation duration? We can put in start time and end time, but instead of getting the raw value is it possible to, for instance, request interpolated results at 1h time b...
Robert Reed almost 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

Need to be able to trend calculations or constants (limits)

I cannot reproduce this in PI Vision. I need to be able to add limit lines to trends. I previously did this by adding a PI calculation set at a constant value.
Guest almost 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 2 No status

Better feedback for errors in ad hoc calculations

Direct quote from customer, "The suggestion is for the ad-hoc calculation parser to highlight where any parsing errors are. Currently it just says there is an error and it often takes a while to find it." Currently when clicking the Preview butto...
Brent Bregenzer almost 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

Provide support for Modbus function code 20

Provide support for Modbus function code 20
Guest almost 4 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Define more explicit system requirements for PI Interfaces

Define more explicit system requirements for PI Interfaces. According to a customer, despite the Buffer and Bandwidth Calculation Spreadsheet, currently available information does not allow for accurate hardware sizing.
Guest almost 4 years ago in PI Interfaces / Installation 0 No status

PI ICU should not allow PItoPI COLD failover configuration

As of version 3.8.1 COLD failover is no longer supported by the PI to PI Interface (https://techsupport.osisoft.com/Troubleshooting/Enhancements/19255OSI8). However, the PI Interface configuration utility still allows COLD failover to be selected....