To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 104 of 5194

AutoPointSync for OPC DA should work on 64bit servers.

AutoPointSync for OPC DA does not install or run correctly on 64bit servers. As most new servers are 64bit this would seem to be an essential capability.
zubzub over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

change the default behavior of the OPC DA interface to use /DC

per the OPC DA 2.x spec, the OPC server will call us back for all points that have a changes; even those points where we are polling. We have a switch to disable the callbacks for points that are not set to advise: /DC Can we make that the defau...
Clint Ramsey over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI OPCtoCSV Tool: Subbranch filter depth

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. It is possible to filter the items by subbranch however it recurses all sub-subbranches. We have an OPC server with around 20k items that we read into ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI interface for OPC .. UA

it would be useful to have an interface that can connect and retrieve data from OPC UA server. it will help to avoid using any additional software for "downgrading" the protocol to OPC at client side.
ValterFostini over 3 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

PI Vision should connect to all collective members in case a collective member is unavailable

Currently, PI Vision connects to a single collective member based on the priorities set in the AFSDK KST (known server table). However, if that collective member becomes unavailable due to an issue (pairchss crashing, network etc etc), the PI visi...
GaryYegiazaryan about 3 years ago in AVEVA™ PI Vision™ / Administration 3 No status

Optimize the attachments table in the PIVision SQL database

The attachments table in the PIVision SQL seems to have 1 line for each image, even if the same image is used multiple times (on different displays or even in the same display). This causes our attachments table to represent more than 50% of the s...
VMichiel 11 months ago in AVEVA™ PI Vision™ / Administration 0 No status

Display Utility: Support adding prefix to PI tag names when copying displays

The PI Vision Display Utility allows modifying the PI or AF Server/Database when copying displays from on PI Vision server to another, but it does not support modifying PI tag names. We are syncing tags between environments and using prefixes to ...
Ryan McErlean over 3 years ago in AVEVA™ PI Vision™ / Administration 0 No status

mettre le feedback portal en Français

mettre le feedback portal en Français
bernard metzinger about 1 year ago in AVEVA™ PI Vision™ / Administration 0 No status

AVEVA PI Vision Status Report

ProcessBook has a quick glance "display status" indicator located in the bottom right corner of all displays. The indicator would be green if the display status was good and red if something was wrong. When the user double-clicks the indicator, a ...
Brian Bolton over 1 year ago in AVEVA™ PI Vision™ / Administration 0 No status

PI Interface for OPC DA bitmask plugin with float data type

PI Interface for OPC DA has a plugin called "Bitmask" to extract specific bits from regular OPC values that are of type Int (i.e VT_I2 / VT_I4 / VT_UI2) but other data types such as floats are not supported. It would be good to have Float data typ...
Guest about 1 year ago in PI Interfaces / PI Interface for OPC DA 1 No status