To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 99 of 5194

Bitmask Functionality in AVEVA PI OPC UA Adapter

During the migration from the PI OPC DA Interface to the AVEVA PI OPC UA Adapter, we noticed that the ability to apply bitmasks to incoming values is no longer supported. This functionality is critical in many existing implementations, especially ...
Dennis Fendel 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Future consideration

Include the "Include variables having historical data only" flag for the OPC UA Adapter

The OPC UA Connector has a feature that should also be included with the AVEVA Adapter for OPC UA : UserAccessLevel=HistoryRead - No real time data to subscribe for and only has historical data stored Please add this feature to the adapter.
Joshua Weishaar about 1 month ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Allow configurable PI Point Lookup priority whether to use PI Point name or PI Point ID first

Currently, in PI Vision display, PI Points data items are stored using both the PI Point ID and PI Point Name. During data retrieval, PI Vision prioritizes resolution via PI Point ID and only falls back to PI Point Name if the PI Point ID is not f...
Mohammed Al-Shaikh 3 months ago in AVEVA™ PI Vision™ / Administration 0 No status

PI Adapter for OPC UA Array Support

As a PI System Administrator, I would like for the PI Adapter for OPC UA to support array data types from the OPC UA Server. A large amount of our data may be contained within arrays on our OPC UA Server, so we would not currently be able to colle...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 12 No status

Identification of unused PI Vision displays

Currently the PI Vision "Display usage information" report only shows displays that have been accessed at least once. It should also show displays with zero accesses, which are an indication that they might not be needed anymore. By identifying un...
victor.guiotoku about 1 year ago in AVEVA™ PI Vision™ / Administration 0 No status

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

New access level to restrict display sharing

We need a new access level with below privileges: - Read shared displays - Create & save displays - No access to share displays with others Most users in Vision like to explore and save their displays. Only access level for that is Publisher. ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Administration 2 Declined

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 15 Planned

Vision - AIM login page to fully disable Windows AD login, and only allow OIDC

Currently, with Vision + AIM OIDC, during AIM login when accessing the Vision, we can still enter Windows AD credential and successfully login to Vision provided there's an OIDC mapping for the Windows AD credential This can be very confusing for ...
Ee Sheing Lee 3 months ago in AVEVA™ PI Vision™ / Administration 0 No status