To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 157 of 5194

Using more complex calculations involving the current time ('*') variable.

I made a Pi page containing calculations from several assets in our system. The result gives a flat number. It would be even more helpful If I could slot that equation into the current time calculation formula. For example, instead of doing " '*'+...
Guest about 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Make data fetching in PSE and PI Vision consistent to avoid No Data

Rework the way PI Vision fetches for analyses so that if the output is calculated in AF, then it can be shown even if one of the inputs is missing (current behavior is described in PI Vision displays unable to resolve certain AF Data References - ...
Guest about 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Enhance AutoPoint Sync APS to sychronize point sets larger than 100,000 points

https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01426 PI AutoPoint Sync is a 32-bit application an can only synchronize 100,000 points in a point source. Recommend to develop the application to use a 64-bit architecture to h...
Luke Peters over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Data Cap on CSV Export

Hello, When I export data in the "csv" format, there is a cap of how much is exported. The cap is 3601 rows of data. Only data up to 3601 rows is populated. Would it be possible to remove this cap and export all data? For instance, my team expor...
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Would like to have data export functionality from ad hoc displays

No description provided
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 No status

Use Both AF Element Attribute and PI tag in a Calculation

Currently I can have a calculation that is made of Only AF Elements Attributes OR PI Tags. It would be nice to have the ability to create calculations that can use both Attribute values and Tag values
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

DNP3: handle invalid timestamps from the RTU

If the RTU provides a timestamp of 0 when using RTU provided timestamps, which does not conform to the DNP3 spec, allow the option to timestamp the event with PI time or drop the event altogether. Note: This was previously Enhancement 123208.
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

When Citect Interface loses connection to a device, throttle errors relating to failed tag reads

OSI PI Citect Interface The interface will log an entry to the message log for every tag that it can't source data for. This is fine for a small number of tags that have not been able to read data from Citect. However, when a Citect Unit (eg PLC)...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

PI Interface for CAISO Exclude Certain Batch Types

We would like the PI CAISO interface to parse through the .XML files and exclude XMLs that contain certain specified . Only certain batch types contain valid data for consumption.
Guest over 3 years ago in PI Interfaces / Other Interfaces 1 Declined

PI-SNMPTrap interface request support for SNMPv3 trap

PI-SNMPTrap interface currently only has support for SNMPv1 and SNMPv2C trap. Feature request for PI-SNMPTrap interface to include support for SNMPv3 trap. Monitoring of snmp traps originating from CISCO switch devices require support for SNMPv3 ...