Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 125 of 5198

Filtering tag with another tag

It would be very useful to be able to filter data with a different tag than the one we want to filter.
esancha over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Edit legends for XY Charts

This is already a capability for normal trends. It would be useful to be able to put in custom names for trends on XY charts and not be stuck to the default data point name.
Guest almost 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Zooming in on plot results in visual change in binary Calculation from always 0 to sometimes 1 . Bug?

I implemented a PI Vision Calculation to implement a binary trend that shows a '1' spike when a value suddenly changes. My goal was to identify at a glance sudden changes for long x vs time plot time durations (those events happen to be very rare)...
Guest almost 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 No status

Add more syntaxes (as in Excel for example)

Would add so many more useful graphs, tables and calculation available. For example add number of alarms going off, number of errors found, countifs, ifs and so on.
Guest almost 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Support of EEC (Elliptic Curve Digital Signature Algorithm ) Certificates

Make the Connector, DCM and Relay support EEC (Elliptic Curve Digital Signature Algorithm) Certificates in future versions. Admin Certificates can be exchanged manually usinmg netsh, but the usage of RSA encrypted certificates is required here.
Julian Baur about 3 years ago in PI Connectors / General 0 No status

Using more complex calculations involving the current time ('*') variable.

I made a Pi page containing calculations from several assets in our system. The result gives a flat number. It would be even more helpful If I could slot that equation into the current time calculation formula. For example, instead of doing " '*'+...
Guest about 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Make data fetching in PSE and PI Vision consistent to avoid No Data

Rework the way PI Vision fetches for analyses so that if the output is calculated in AF, then it can be shown even if one of the inputs is missing (current behavior is described in PI Vision displays unable to resolve certain AF Data References - ...
Guest about 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Put a PI Collective note directly on the Server List page

The PI Connector user guides mention "For a PI Data Archive collective, add each member of the collective to the PI Data servers list, not the collective itself." It would be useful to have this note directly on the Server List page.
Kenneth Barber over 3 years ago in PI Connectors / General 0 No status

"Connected" to invalid PI Data servers

If I add an invalid PI Data server in the Server List page, the PI Connector will say that it is connected to this data source. The status only becomes "Error" when the PI Connector tries to save data to this server. Please change this so that inv...
Kenneth Barber over 3 years ago in PI Connectors / General 1 No status

Warning when stopping a connector about potential consequences

Some connectors perform some kind of rediscovery of the data source upon start - Such as meta data or current values, etc. When stopping a connector from the UI, a warning should pop-up indicating potential consequences of doing so and what to exp...
Guest over 3 years ago in PI Connectors / General 1 No status