To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 397 of 5219

Trilinear Interpolation

The ability to utilize three columns as input for interpolation from an AF Lookup Table to determine the result for a fourth column could be beneficial for predictions and analysis. Currently, only linear and bilinear interpolation is possible fr...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Function to extract Data Reference Type

We would like to be able to extract the data reference type (PI Point, None, Formula, Table Lookup, etc.) for an attribute using PI Analysis, similar to the TagType function for PI points.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Improve usability of TagNum function

The TagNum function seems to be the only function that requires a double quote as opposed to single quotes. Many other TagXXX functions call for single quotes for its attribute or PI Point arguments.
Jinmo Yi over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Thorough Analysis service message logs

Having more thorough and detailed messages for the Analysis service in the event logs, especially upon startup. Environment details + Language settings that the Analysis service is using should be mentioned in the startup logs in order to better ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow Analysis timestamp override feature to output milliseconds

When using an analysis variable as the output timestamp, it appears that the actual output timestamp is floored to the nearest second, shaving off any millisecond count. This is not a huge priority on our end, but I wanted to ask in case it was a ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Remove tag need for Exit() and NoOutput() in analysis

Allow analysis outputting to Analysis Data Reference attributes to make use of the functions Exit() and NoOutput(), instead of requiring only PI Point Data Reference attributes.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Show calculation inputs with a single action when viewing the calculation result

If one is viewing a calculated value on a trend, for example, it would be helpful to take one step to see the values behind that calculation for troubleshooting purposes.
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 Declined

Create PI ProcessBook Support Tool add-in to replace data sets in PB displays with other data references before migrating to PI Vision

As described in PI System Analytics: Which tool is best for the job? (https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB00868), OSIsoft recommends using asset analytics instead of PI Calculation data sets to create calculation...
Jeremy Roberts over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 Declined

Function Text

Ability to add text containing basic functions (add, subtract, multiply, divide) using data pointing to number assets.
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Auto convert decimals to hours/minuets

No description provided
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status