To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Add a configurable Quality field mapping to the AVEVA Adapter for MQTT, using OPC UA status code semantics (Good/Uncertain/Bad).

Summary The AVEVA Adapter for MQTT currently allows a custom field to be defined for mapping the timestamp from a JSON payload. We request the same capability for data quality: a configurable data selection property that identifies which payload f...
Matthew Kishe about 2 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Use calculation as tags

It would be nice to be able to propagate calculations within PI by calling for other calculated variables within a new calculation. For example, where X, Y, and Z are PI Tags, I have a calculation A = X+Y. I would like to add a new calculation B...
Guest over 4 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 No status

OPC UA Adapter should validate/disallow unsupported StreamId characters (or warn) instead of URL-encoding and publishing invalid streams to CONNECT

When the OPC UA Adapter discovers tags/names containing unsupported characters (e.g., [ / ]), it publishes StreamIds into AVEVA CONNECT where the characters appear URL-encoded (e.g., %5B / %5D). These streams then fail to receive values and cannot...
David Scott about 2 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Include buffering metrics in adapter health

In the OmfEgress component in adapter health the metrics are limited to DeviceStatus, and IO rate. Another key metric for this component is the buffering state. To keep it simple it would be useful to have the number of events in the buffer. This ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / General 1 No status

Display's Start/End Time in Vision Calculation

be able to have a Vision calc utilize the current start and end time of the display
Matt Voll over 4 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 3 No status

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Planned

Support https instead of http only

No description provided
Gabriel Verreault over 4 years ago in AVEVA™ Adapters / General 2 Future consideration

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 10 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Evaluating

Bitmask Functionality in AVEVA PI OPC UA Adapter

During the migration from the PI OPC DA Interface to the AVEVA PI OPC UA Adapter, we noticed that the ability to apply bitmasks to incoming values is no longer supported. This functionality is critical in many existing implementations, especially ...
Dennis Fendel over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Future consideration

PI Tag Mapping configuration in the background of PI OPC UA Adapter to use Point ID

The CSV / JSON file in the background will have the mapping between the OPC UA Server tag against its' respective PI Tag Name. In such case, if we need to change the tag name after sometime, then which results in multiple process like stop the Ada...
Navaneethakrishnan 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status