To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Allow Units of calculations to be used in displays, not only on top but to the right, left or below.

A tag is giving a simple calculation e.g. TAG_MW * 1. But the calculation has no where to specify the engineering units and it also does not derive that MW * 1 will still be MW. When you place this on the diagram you cannot place the units to the ...
Guest 7 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Enhance the OPC Interface to specify which groups are not receiving data

When a polled group does not receive data for more than 2 scan cycles, the interface updates the device status health point to 5 | Error | One or more groups not getting data. It will be useful to also specify which scan classes did not receive da...
Guest almost 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Support Werum PAS|X 3.2 and PAS|X Data Access (PDA)

Werum has recently released the next version of their PAS|X Database, and it bolsters a new method of Data Access. OSIsoft will need to release an re-tooled version of their PI Interface for Werum PAS|X to support this latest Werum version and the...
Ellery Murdock almost 4 years ago in PI Interfaces / Batch Interfaces 1 No status

Adding Radar Diagram/Spider chart

please add Radar diagram it is helpful for power plant to check the exhaust tempreatures
Guest almost 4 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 2 No status

Add option to specify Calculation Basis in PI Vision Calculations

Add a configurable option for Calculations in PI Vision to specify a Calculation Basis of Continuous or Discrete when performing summary calculations. Due to a limitation on the PI Data Archive, PI Vision summary calculations currently can treat ...
Guest almost 4 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Name & Column of Vision Calculation Multi-state Source needs to be visible

If a PI Point or an AF Attribute is used as a Multi-state Source, then hovering the cursor over the source in the Multi-state configuration panel reveals the full name/path of the source. But if a Vision Calculation is used, then the Name and Colu...
kliffhopson over 1 year ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Multistate does not recognize value in calculation (Text)

Allow multistate to recognize text
Guest 11 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Support Regex engine in the message filters

It would be nice to have regex matching and replace in PI UFL ini files. Also, would be nice to have anything other than ASCII encoding support (ex UTF-8..with/without BOM, etc) Use cases: ex. we need to parse timestamps where year has either 2 o...
Guest almost 4 years ago in PI Interfaces / PI Interface for UFL 1 No status

Enhancement for Advise tags to poll  OPC server when Excmax expires

Currently, when an advise tag does not get a value in an ExcMax period,  the interface will send the same value to PI over again without going to the OPC server (assuming that the OPC interface has not disconnected from the OPC server during ...
Guest almost 4 years ago in PI Interfaces / PI Interface for OPC DA 3 No status

Batch Framework Interfaces - [TIME] placeholder should consider whether TS=LCL is configured

Batch Framework Interfaces - [TIME] and [TIMESTAMP] placeholders should consider whether TS=LCL is configured (meaning the interface is processing incoming events as Local Time). Currently, values of these placeholders always show up as GMT timest...
Guest almost 4 years ago in PI Interfaces / Batch Interfaces 5 Planned