To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 158 of 5192

On Event Comparison Displays, be able to organize attributes in custom order

Currently on Event Comparison Displays, attributes are ordered in alphabetical order. I think it would be very useful to be able to order them in any custom order. Some attributes are better to be viewed together.
Carlos Sagbini almost 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 0 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Simplify the security configuration for OPC UA

The newer OPC UA protocols have stricter security standards, which is good, but that makes configuring connections more difficult, especially with regard to the need to put in tunneling and open ports. It should be easier to establish a secure con...
Laurie Dieffenbach about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide possibility to create stream metadata from table data

Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status information ...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Add the ability to hide similar child events

On a batch with several wait times in between different phases it would be nice to be able to hide those waiting times (child events) to allow for better comparison of the actual sequences.
Guest over 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 0 Declined

multiple ways to show values

Hi - there should be a possibility to add multiple thresholds to the trends, to compare and easier display high and low values. Also it would be great if the lines could change from vertical to horizontal to show the range.
Guest over 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 0 No status

Provide alternative navigation link in events table

The Event frame drilldown can be useful but in many cases we would prefer to link directly to a pi vision screen for the primary elements for each event. It would be great if we could set up a link like can be done for most other objects in vision...
Guest over 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 1 No status

Filter Assets by List

Filter element/asset by list (separated by comma, for example). Currently can only filter on one exact name or wildcard, which can return too many assets. In fact PI System Explorer can also use this feature (filter base on a list of elements).
Barry Hu over 3 years ago in AVEVA™ PI Vision™ / Event Comparison Displays 1 No status