To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 113 of 5194

PI Interface for Ramp Soak Simulator Data - Update Time Period To Seconds

To simulate data using the PI Interface for Ramp Soak Simulator Data, the ExDesc of the PI Point needs to be of the format: (period, end_value) period is the time in minutes. end_value is the value for the tag at the end of the phase period. Cur...
Mohammed Qasim Asghar 8 months ago in PI Interfaces / Other Interfaces 0 No status

Install Wizard: Allow for Opting Out of SQL Script Execution

Allow for the ability to opt out of Go.bat execution again SQL during the installation or upgrade of PI Vision like the AF Services kit does. Currently, the kit tries to execute those scripts automatically and errors out with "The PI Vision datab...
Guest over 3 years ago in AVEVA™ PI Vision™ / Installation & Upgrading 1 No status

PI Interface for IEEE C37.118 support for Analog data Signed and Unsigned 16-bit Integers

The IEEE specification of the IEEE C37.118 protocol does not specify if analog data should be singed or unsigned for 16-bit integers. The currently the PI Interface for IEEE C37.118 represents these values as exclusively unsigned. Both types shoul...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Enhance WMI interface to verify that ACE Class Libraries are running

PI-ACE Manager looks at the PI-Module Database to see if the individual modules are running. The Class Library sub-processes updates the PI-MDB when it starts & stops. If the process dies, it does not always update the PI-MDB values. So, there...
Joe Staublin over 3 years ago in PI Interfaces / Other Interfaces 1 No status

PI Vision - Software as a Service (SaaS)

Be able to consume PI Vision as a Software as a Service (SaaS) offering where installation and upgrades are managed by OSIsoft as part of the offering.  PI Vision would be able to connect to data that lives in on premises PI / AF Systems.
Guest over 3 years ago in AVEVA™ PI Vision™ / Installation & Upgrading 2 No status

Built-in SQL database backup job

As a PI Administrator, it would be useful for the PI Vision SQL database installation to also create a PI Vision SQL database backup job like the AF SQL Scripts already have. That way I do not have to configure the PI Vision SQL backup job manuall...
Guest over 3 years ago in AVEVA™ PI Vision™ / Installation & Upgrading 0 Declined

OPC AE: add history recovery feature

There is a stronger market demand to have more alarm data in PI so that the alarms can be analysed together with the process data. Existing (as of Oct 2019) PI OPC AE Interface does not support history recovery. Without the history recovery featur...
AM(CSL) over 3 years ago in PI Interfaces / Other Interfaces 0 No status

PI AMI Itron Interface support for TLS1.3

PI AMI Itron Interface currently supports TLS1.1. Microsoft ended support for TLS1.1 in March 2020. To keep the PI AMI Itron Interface usable with latest browsers, please update to support TLS1.3.
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 Evaluating

Implement PI Vision SQL Database Schema Version Checks

Because PI Vision upgrades exist in two parts (application, database), the database portion may be omitted accidentally on occasion. In these situations, it would be useful to implement application pool checks to ensure the database schema version...
Guest over 3 years ago in AVEVA™ PI Vision™ / Installation & Upgrading 0 No status

DeltaV Smart Connector configurability

Smart Connector foo DeltaV should let user configure some default attributes for tags created: - User should be able to define what the default point security should be - User should be able to decide if tags should be created as Poll or Advise
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status