To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 165 of 5219

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Make the graphic transparent just like we can do with shapes

If we use Hollow or Solid and put the color as the same as the display background, some graphic still shows some faint outline. It would be good if this outline could not show anymore
Guest almost 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status

PI Vision authorization window

The folder authorization setting screen has a wide window, but the screen authorization setting screen can only display two groups, making it difficult to find the target group. Is it possible to widen the window?
Kosuke Ono almost 2 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status

Group Multi-State

I have a situation where the results of a tag determine the data to be shown on a display. For example: if the results of Tank Selected is Tank 01, then these 8 tags results are shown on the display. If Tank Selected is Tank 10, then these 7 tags ...
Brian Bolton almost 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status

Trend: Hide scales for sparkline trend, when resized to small enough

Allow trend lines to be collapsed to a sparkline without scale axis/tick marks, similar to the sparkline in the table view. The guage can be collapsed without any scales, but the trend retains a scale tickmark. See sample.
Guest over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 Declined

Flip your own shapes

The option to flip horizontal/vertical with the shapes that you draw and not just the contents of the graphics library
Guest over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 Declined

The ability to change the gradient or transparency of the zoom buttons in PiVision screen or add a box around buttons to make more visible

There needs to be a way to have the ability to change the gradient or transparency level of the zoom buttons in PiVision screen or add a box around buttons to make more visible on light or white backgrounds in PI Vision. In ProcessBook there was a...
SSage1 over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status