Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 88

Correct pointDB_RemoveEmptySource behaviour or change Point Source Management

Hello, About the tuning parameter pointDB_RemoveEmptySource the following Article : https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01008 Indicates : Perform any of the following actions to trigger removal of empty point sou...
Lionel Gergaud almost 2 years ago in AVEVA™ PI Server / Data Archive 2 No status

Include Windows Counters/OMF Health for Message Log Event Rate

Having metrics that count the number of messages being written to the message log, and categorized by severity, gives a great dashboard overview of the status of PI data archive. For example, having a events/min count of error messages historized ...
Mike Horrocks over 1 year ago in AVEVA™ PI Server / Data Archive 0 No status

PI SMT's Archive Editor should support manually adding NULL values

Archive Editor in PI System Management Tools should support writing NULL values (ie, empty strings). This is currently supported by other PI Clients. For example, it is possible to write empty strings using PI System Explorer as well as using a PI...
Bethany Jewett 12 months ago in AVEVA™ PI Server / Data Archive 0 No status

As a PI Administrator, we should be able to see which PI mapping was used for a Windows AD user in PI message logs.

Through PI message logs I want to see which PI mapping was used for a Windows AD user, currently only the PI identity associated the windows AD is visible in the Logs. PI mapping information will give us more idea/facts about the particular Window...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

Method to backup and restore PI Points only

The PI backup tools currently do not have a method to backup only the files related to PI Points. The purpose of this would be to refresh the point table on a QA system from a production system. The current PI backup method is all or nothing.
GaryYegiazaryan over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

Negative numbers in digitalsets

Negative numbers in digitalsets for all PI interface and skip numbers, basically that the digitalset is like the enum of AF
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

PI Server is taking a lot of resources to interpolate a value before the first archived value

In a rescent issue we faced, we discoreved that when you try to interpolated a value before the first archived value on a system with a lot of archive files, the system must read all the archive files trying to find a previous value for interpolat...
marc.cote 7 months ago in AVEVA™ PI Server / Data Archive 0 No status

Ability to Identify Critical (e.g. GxP) PI Tag in SMT

A checkbox or some mechanism to identify Critical data point (e.g GxP) in SMT. * can be used for search filter to separate critical vs. non-critical data (gxp vs non-gxp) * possible additional layer of confirmation/prompt prior deletion (?)  ...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

Built-in feature to automatically move archive files past a certain age to a different directory

Automatically move archives from a disk to another based on their age. Use case: I only want to keep the last 2y of data on a SSD and the remaining will be stored on a regular disk. My use case can be achieve using the example PowerShell script l...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

When archive corruption is noted, automatically force a shift to a new archive

As a PI system user and administrator, I am interested in minimizing data loss due to a corrupted Archive. Please include an automated fix when corruption is noted. The PI server could force a shift to a new archive and re-processes the corrupted ...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status