To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 202 of 5222

Ability to disable file renaming for AVEVA Adapter for Structured Data Files or PI UFL products.

The pharma industry has to abide to GMP regulations, in this scenario, the original files should not be modified or renamed. It would be good to have an end to end solution with PI System products instead of making copies of the original file.
Alex Santos almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

Include [optional] unit of measure in the data selection configuration.

Some data sources do not provide a unit of measure. It would be useful to be able to specify the unit of measure as part of the data configuration so that this information is provided to EDS/PI/ADH through the data flow.
Mike Horrocks almost 2 years ago in AVEVA™ Adapters / General 1 No status

Edit legends for XY Charts

This is already a capability for normal trends. It would be useful to be able to put in custom names for trends on XY charts and not be stuck to the default data point name.
Guest almost 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Allowing the MQTT adapter to set PI Point attributes during the creation process

we're interested in having the ability to configure the zero, span and some other points parameters during the creation of the PI points. currently when points are created. they're defaulting to zero=0 and span=100. while also displaying Boolean p...
Guest 11 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Zooming in on plot results in visual change in binary Calculation from always 0 to sometimes 1 . Bug?

I implemented a PI Vision Calculation to implement a binary trend that shows a '1' spike when a value suddenly changes. My goal was to identify at a glance sudden changes for long x vs time plot time durations (those events happen to be very rare)...
Guest almost 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 No status

Add more syntaxes (as in Excel for example)

Would add so many more useful graphs, tables and calculation available. For example add number of alarms going off, number of errors found, countifs, ifs and so on.
Guest almost 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

host adapter(s) as a service

SaaS solution for customers with benefits thereof.
Guest about 2 years ago in AVEVA™ Adapters / General 1 No status

Using more complex calculations involving the current time ('*') variable.

I made a Pi page containing calculations from several assets in our system. The result gives a flat number. It would be even more helpful If I could slot that equation into the current time calculation formula. For example, instead of doing " '*'+...
Guest about 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Make data fetching in PSE and PI Vision consistent to avoid No Data

Rework the way PI Vision fetches for analyses so that if the output is calculated in AF, then it can be shown even if one of the inputs is missing (current behavior is described in PI Vision displays unable to resolve certain AF Data References - ...
Guest about 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status