To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 79 of 5194

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add the ability to hide the domain of a logged-on user

Provide administrators with the ability to hide or obscure the domain of users logged on to a Vision server (instead of domain\userID in the top right, it would just show userID). Creating on behalf of a customer, for who the Vision server is hos...
Guest over 3 years ago in AVEVA™ PI Vision™ / Security 0 Declined

setting the number of  a single account's Multiple concurrent login

The administrator should have permit to set the number of  a single account's Multiple concurrent login.Now my account can login on multiple terminals at the same time without limit.
Guest over 3 years ago in AVEVA™ PI Vision™ / Security 0 Declined

Restrict view of Events details after double-clicking on an Event frame in an Events table

As a PI Vision administrator, I would like to restrict or disable access to view Events details after double-clicking on an Event frame in an Events table on a PI Vision display for specific PI Vision users
Guest over 3 years ago in AVEVA™ PI Vision™ / Security 0 Declined

PI Vision support for OAuth 2.1

PI Vision's current CTP claims implementation is based off of OAuth 2.0. With OAuth 2.1 coming out PI Vision's claims implementation will need to be revised to be compliant with the new version of the framework. Specifically OAuth 2.1 is removing ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Security 0 No status

Parameter for restarting the interface if no connection to the OPC server can be established after a defined period of time

We use the Phoenix Contact Firewall with the OPC Inspector. When the OPC server restarts or breaks the connection for a few seconds, the firewall blocks all ports except port 135. After initial connection through this port, new firewall rules are ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to the OPC DA Interface so that the user can adjust the maximum advise tag exception delay for Event/Trigger tags

This affect to delay in Event\Trigger points. KCS: Delay in Event Points. When using Event Points, we purposefully do have a delay (if excMax is > 2 s then 2 s else 0.9*excMax) for advise tags (Trigger Point) before they're sent to the PI Serv...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to UniInt so that the user can adjust the minimum wait time for checking for new events from the Update Manager

This affects the delay in Event\Trigger tags. KCS: Delay in Event Points. The largest and most variable delay seems to come from the time the event is written to the PI Server and the time the interface (UniInt) picks, which is between 0ms-1,000m...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA Interface to run on Microsoft Visual C++ 2015-2022

Can only install OPC DA Interface (2.7.2.20) with "Microsoft Visual C++ 2015-2019 Redistributable" installed.
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 1 Planned

Any Patches/Updates needed to be ready for Microsoft's DCOM hardening in 2023?

By March 2023 Microsoft will enforce a patch that upgrades DCOM security. Some applications that use DCOM (such as the PI OPC interface) will require some updates to continue to work. Are there any updates that I need to apply on any of the PI com...