To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Symbols

Showing 267 of 5044

Modify the scale step for PI Vision symbols (gauges, trend)

When customizing symbol scale range, only top and bottom values can be specified. It would also be useful to set increment or step value to avoid unnecessary clutter on a display.
Guest over 2 years ago in AVEVA™ PI Vision™ / Symbols 1 No status

Sampled Data Symbol

Please add a Pi Vision Symbol for Sampled Data (similar to Data Link in Excel) to show a row column timestamped historical data table for selected tags. This would be similar to the Trend, only in table format for the time period at the bottom of ...
Guest over 2 years ago in AVEVA™ PI Vision™ / Symbols 1 Declined

Option to disable trend cursor sync

Not all users like synchronized trend cursors (placing a cursor on one trend causes it to appear on other trends at the same time), some find it very distracting. There should be an option to disable this functionality.
Ryan McErlean over 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Bad value indicator

Have a bad value indicator on value symbols - A triangular indicator specially in the value symbol which would indicate an exclamation mark when the quality of the data value is bad.
Ryan McErlean over 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Add events table to collection

To be able to have event tables within Collection (this is mandatory) Event tables are feed with events matching the collection asset. It is different than the idea https://feedback.osisoft.com/forums/320517/suggestions/35062504
Gael over 2 years ago in AVEVA™ PI Vision™ / Symbols 1 No status

Single Gauge with Multiple Values

Configure gauges using multiple attribute values. As an example, if you have a tank that has 2 level sensors, it would be helpful to show both levels in 1 gauge. Currently we accomplish this by creating 2 gauges and putting 1 on top of the other, ...
holemn over 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Plot markers for all archived events for step tags

When plotting a tag with the "step" attribute on in a PI Vision trend with the scatter plot trace option, not all archived events are shown. A workaround is to create a Formula Data Reference attribute in AF that points to the tag with the stepped...
Guest over 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Ability to re-size grouped symbols without un-grouping

It appears that you have to un-group symbols in order to resize them. As an example, we can have a symbol of a pump, the pi value of current pressure, and then a title tag all grouped together. It gets difficult to efficiently update displays when...
Borgh over 1 year ago in AVEVA™ PI Vision™ / Symbols 0 No status

Collection: Sort attribute values by value by full element path

PI Vision collection sort order is not using the full element path to sort the display of the attribute values. We have a templates for 180 element items. Each element also has 4 sub-elements. When creating a PI Vision symbol using an attribute fr...
Simone Clement almost 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Configurable XY Plot scale intervals

Be able to configure the scale intervals of XY Plots. Currently while it is possible to customise the scale range of the axes in XY Plots, it is not possible to be able to specify the scale intervals to be used.
Miwa Teranishi over 1 year ago in AVEVA™ PI Vision™ / Symbols 0 No status