Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 466 of 5258

Log bad timestamps for the PI RDBMS Interface

When the PI RDBMS Interface gets a bad timestamp from the source RDB that it cannot coerce into a PI Timestamp, the actual bad timestamp received from the RDB should be logged as part of the error message. This would coincide with the following e...
Guest over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 Future consideration

efgen

Allow EFGen to use a Mix of PITAG + Text for the Creation of event frame names . Concatenate a Text + PITAG for example
valeman over 3 years ago in PI Interfaces / Batch Interfaces 4 No status

PI BACnet interface: add support for BACnet Setpoint object

Add support for BACnet Setpoint objects in the PI BACnet interface.
Kenneth Reiss over 3 years ago in PI Interfaces / Other Interfaces 1 No status

Update GE iFix interface compatibility information

As an interfaces user, I would like to know which versions of iFIX and Windows Server OS are compatible with the PI Interface for GE iFix so that I can determine whether this interface is suitable for my use case. The last update for this interfa...
Guest over 3 years ago in PI Interfaces / Other Interfaces 1 No status

AF Transformer logging improvements

Improve AF Transformer logging: In some cases it's hard to investigate why AF Transformer doesn't include certain elements in transformation. it would be helpful to have a debug level that enables following features: - log element names that were ...
Guest over 3 years ago in AVEVA™ PI Server / General 1 Declined

Allow passing parameters to XML script file so that I can maintain one general script for many sites

Below in the examples are the parameters that would change from site to site.  Other than these parameters the transformation XML script is identical across sites.  With parameters, it would be simpler to maintain these files. • Host, D...
Guest over 3 years ago in AVEVA™ PI Server / General 0 Declined

Support multiple Modbus devices on the same machine

Add support for multiple Modbus devices (using the same IP address but different port numbers) on the same machine. For example, the interface could allow the user to configure something like this: /dn= xxx.xx.xxx.xx:43120,/cn=1,/polldelay=0,/to...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

and operator

Add a function that can be used in the UFL Configuration File to perform bitwise operations. For example, a function similar to the AND operator in Performance Equations and Asset Analytics.
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 1 Declined

PI interface for OPC .. UA

it would be useful to have an interface that can connect and retrieve data from OPC UA server. it will help to avoid using any additional software for "downgrading" the protocol to OPC at client side.
ValterFostini over 3 years ago in PI Interfaces / PI Interface for OPC DA 3 No status

DeltaV Smart Connector Enhancement

I think it would be a good idea to allow exception settings to be created. The DeltaV history collection settings only allow for compression. Since many/most users use 1/2 compression for their exception value then perhaps we could have a check bo...
Guest over 3 years ago in PI Interfaces / General 0 No status