Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 84

PI Tag Notes

A way to add notes to a PI tag at a certain time, with an indicator that will appear any time that tag is trended during that time period. For example when a worn pump is replaced we see a step change in motor amperage. It would be nice if a note...
Guest over 3 years ago in AVEVA™ PI Server / General 1 No status

Revise Perfmon counter for PIBufss - Point Count

We are trying to use this perfmon counter as a diagnostic aid to catch issues with a third party interface, but it could be used with PI interfaces. We are checking to see if the point configuration for their interface matches across the four poss...
Guest over 3 years ago in AVEVA™ PI Server / General 0 No status

Enable suppression of certain error messages in HABConnect interface

Related to this article: https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=000031389 I may have keys that are all spaces, and this may result in constant logging of the following error upon every database refresh (determined by...
Paul Kim over 3 years ago in AVEVA™ PI Server / General 0 No status

General Feedback

Hello, I don't see any roadmap from OSIsoft/AVEVA for the currently supported products. Looks like OSIsoft decided collect SRP for the existing OSIsoft software products and promote only the AVEVA products. Thanks, Subburaman Sankaran
Guest over 3 years ago in AVEVA™ PI Server / General 0 No status

Allow data update for future PI Points in PI OPC DA Server

When a future pi point is published in the OPC DA server current value matches PI DA current value but it does not update new events on the PI DA You need to create another group in an OPC client or close the connection and reconnect to see new va...
asanzacedo over 3 years ago in AVEVA™ PI Server / General 0 No status

Spelling mistake in Archive_AutoArchiveFileSize's description

In the description of the tuning parameter Archive_AutoArchiveFileSize, "occurs" is misspelled as "occurrs". This misspelling is also followed by a semicolon instead of a period.
Kenneth Barber over 3 years ago in AVEVA™ PI Server / System Management 2 No status

GUI to edit bitmask tuning parameters

Currently, bitmask tuning parameters are entered and displayed as a single number. Not every PI administrator will know that a bitmask involves the addition (or "ORing") of each bit to combine their effects. It is also time-consuming and error-pro...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / System Management 1 No status

Show pending changes in the Archive Editor of PI System Management Tools

Currently, there is no visual distinction between: • rows that contain no changes, • rows that contain unsaved changes, and • rows that contain saved changes that have not been processed by the PI Data Archive yet (this happens when you refresh to...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / System Management 0 No status

Archive Editor: Preserve the selection of multiple rows when right-clicking on a cell within the selection

Currently, if you select multiple rows in the Archive Editor and then right-click on a cell that is not the ► cell or the Value cell beside it, your selection will collapse to the row whose cell you right-clicked. That is, no matter how many rows...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / System Management 1 No status

option to manually disable secondary collective member synchronization

I have experienced several synchronization errors with data archives running on virtual machines in separate errors, generally after MS updates. Please provide a way to stop synchronization of configurations between collective members, so I can pe...
Guest over 3 years ago in AVEVA™ PI Server / System Management 1 No status