To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 250 of 5192

Expand the plug-ins by default when PI System Management Tools is opened

PI administrators that keep their PI system up to date will likely hide all of the many deprecated plug-ins in PI System Management Tools. There are few enough plug-ins remaining that the left pane can be fully expanded to show all remaining plug-...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / System Management 1 Declined

PI SMT - Archive Editor Improvements

Why is the second server of all selected servers the default selected server for the archive editor? (C# index 1 instead of 0?) If I leave the Tagname empty and press the search button the tag search dialog opens fine. But if I enter some text at...
HolgerJoistOmv over 3 years ago in AVEVA™ PI Server / System Management 0 No status

Increase Box Length for Tagname Field in Archive Editor

The Tagname field visible length should be increased within Archive Editor in System Management Tools. The full tag name is limited and cannot tell what is listed because the name is cut off. (See screenshot and steps listed below.) Steps to repr...
Guest over 3 years ago in AVEVA™ PI Server / System Management 0 No status

Expose connection history information to PI SMT

As PI System administrator, I would like to know the number of clients connection given a time frame. (e.g. * -1 month) Currently, this is only exposed to the pidiag command line utility. It would help me as a pi system admin to see it within a us...
Jinmo Yi over 3 years ago in AVEVA™ PI Server / System Management 0 No status

Replace "timeout parameters" with "tuning parameters" in the description of the PITUNING Database Security table

In PI System Management Tools, under the Database Security plugin, the description of the PITUNING table is: "Controls access to Timeout parameters and the Firewall" "Timeout parameters" is the old name for "tuning parameters", I'm guessing from ...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / System Management 0 No status

Make the tuning parameter Base_AllowSIDLookupFailureForMapping visible by default

When this tuning parameter is enabled, it prevents a PI Collective from being flagged as out-of-sync when some of the PI Collective members can resolve the SID of a PI Mapping and others cannot. However, by default, this tuning parameter is hidden...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / System Management 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status