Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 155 of 5194

Allow renaming of diagnostic tags for batch interfaces

Batch interfaces should follow a similar approach to UniInt based interfaces to retrieve the diagnostic tags. That is to say they should pull the diagnostic tags based on the PointSource, Location1, and ExDesc, not a hardcoded name based purely on...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 1 No status

Include MSXML with the latest version of the PI Interface for OPC XML-DA

The Read-Only version of the PI Interface for OPC XML-DA (1.7.3.40) does not contain the msxml4 library necessary for communicating with the OPC XML-DA. The workaround is to install the Read-Write version of the interface and then the Read-Only ve...
Randy Giguere 11 months ago in PI Interfaces / Other Interfaces 1 No status

efgen

Allow EFGen to use a Mix of PITAG + Text for the Creation of event frame names . Concatenate a Text + PITAG for example
valeman over 3 years ago in PI Interfaces / Batch Interfaces 4 No status

PI BACnet interface: add support for BACnet Setpoint object

Add support for BACnet Setpoint objects in the PI BACnet interface.
Kenneth Reiss over 3 years ago in PI Interfaces / Other Interfaces 1 No status

Update GE iFix interface compatibility information

As an interfaces user, I would like to know which versions of iFIX and Windows Server OS are compatible with the PI Interface for GE iFix so that I can determine whether this interface is suitable for my use case. The last update for this interfa...
Guest over 3 years ago in PI Interfaces / Other Interfaces 1 No status

PI Interface for Ramp Soak Simulator Data - Update Time Period To Seconds

To simulate data using the PI Interface for Ramp Soak Simulator Data, the ExDesc of the PI Point needs to be of the format: (period, end_value) period is the time in minutes. end_value is the value for the tag at the end of the phase period. Cur...
Mohammed Qasim Asghar 8 months ago in PI Interfaces / Other Interfaces 0 No status

Allow diagnostic tags per failover node for batch interfaces

Batch interfaces should allow for diagnostic tags per failover node, just like UniInt based interfaces. Currently, there is no differentiation between the diagnostic tags for the primary failover node versus the backup failover node. The Location3...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

PI Interface for IEEE C37.118 support for Analog data Signed and Unsigned 16-bit Integers

The IEEE specification of the IEEE C37.118 protocol does not specify if analog data should be singed or unsigned for 16-bit integers. The currently the PI Interface for IEEE C37.118 represents these values as exclusively unsigned. Both types shoul...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Enhance WMI interface to verify that ACE Class Libraries are running

PI-ACE Manager looks at the PI-Module Database to see if the individual modules are running. The Class Library sub-processes updates the PI-MDB when it starts & stops. If the process dies, it does not always update the PI-MDB values. So, there...
Joe Staublin over 3 years ago in PI Interfaces / Other Interfaces 1 No status

EMDVB - Add Option to End Procedure EF with batchview.endtime equivalent instead of when it's unloaded from the BOI

Currently the EMDVB interface will not end the parent Procedure level event frame until the batch has been unloaded from the Delta Batch Operator Interface. It is very common for users to leave batches loaded for quite a while which causes batches...
Bill Sublette 9 months ago in PI Interfaces / Batch Interfaces 0 No status