To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

My votes: Batch Interfaces

Showing 52 of 4921

PI EFGEN Interface -- Allow the "time true" fuction for EFGen

in order to eliminate unwanted or noise event which be triggered and recovered in a short period.
Guest over 2 years ago in PI Interfaces / Batch Interfaces 0 Declined

EFGEN - Allow Active Point Trigger Based on Specific Value/Logic/Calculation

Using EFGen, currently an EF can only be triggered based on the zeroth state of the Active Point. This makes is impossible to trigger different events based on specific values of a single PI Tag. I am trying to implement a batch structure using ...
Guest over 2 years ago in PI Interfaces / Batch Interfaces 0 Declined

EMERSON PK based DCS - EMDVB Interface support

Emerson has a new PK Controller based DCS available (in lieu of full blown DeltaV). This new device is contained with OPC-UA and Batch Exec/Historian. We want support for the existing EMDVB interface to supply S88 based batches into PI Event Frame...
Guest over 2 years ago in PI Interfaces / Batch Interfaces 0 Declined

Add support for workgroups for PI Interface for Emerson DeltaV Syncade

Add support for workgroups for PI Interface for Emerson DeltaV Syncade
Alan Izar over 2 years ago in PI Interfaces / Batch Interfaces 2 Declined

Data Verification for the PI Interface for Emerson DeltaV Batch

Add a feature that performs a verification check of the data in PI against data in the DeltaV Historian and provide a report of any missing or mismatched data.
Guest over 2 years ago in PI Interfaces / Batch Interfaces 1 Declined

Batch Framework Interfaces - Allow creation of only the Event Frame levels that exist on data source

The BES/MES sometimes contains recipes with no Procedure, or even Unit Procedure. The Batch Framework Interfaces should allow the creation of only the Event Frame levels that exist on the data source. This would need to be enabled with an interfac...
Guest over 2 years ago in PI Interfaces / Batch Interfaces 1 Declined

Allow PI Interface for EMDVB to have the ability to define the source system Time/TimeZone offset.

PI EMDVB interface stops because of time difference between SQL and PI servers: "Error, SQL Server is ahead of PI Server more than 30 seconds, please adjust clocks. " That means we should adjust the (SQL server) DCS clock. However 30 seconds see...
Jose Sanchez Colunga over 2 years ago in PI Interfaces / Batch Interfaces 1 Declined

Batch interface to support slightly different parsing logic

Some of the fields incoming from the DCS are user entered and prone to errors. Please allow for the option to include slightly different logics to be able to filter out those user errors (such as empty spaces at the end of the string, etc).
Alan Izar over 2 years ago in PI Interfaces / Batch Interfaces 0 Declined

Improve the recovery process for long EFGEN batches

Currently if EFGEN is configured to evaluate PI Points at the event end, long batches require recovery start time to be set before the start of the batch. This leads to a long recovery process as many completed batches will be evaluated again.
Guest over 2 years ago in PI Interfaces / Batch Interfaces 0 No status

PI EMDVB Interface - Allow to retrieve "description" column content from SQL DB

The interface can retrieves Report events [Event,value="Report"]. Within these events, [Descript] - parameter returning "category" from SQL database. We could not retrieve "description" column contents from the SQL DB [BReportEvent] table. See cas...