To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 79 of 5194

Remotely view logs

I understand that you can remotely view logs using pigetmsg. However this solution does not work for me as the interface is on a controlled network that only allows outbound traffic. I would like a way for the interface node to be able to push out...
Guest over 3 years ago in PI Interfaces / General 1 No status

Improved handling of PI Write failures

Provide a configuration option in UniInt interfaces, to enable shutdown of the interface if it consistently receives error messages when attempting to write to PI. Recently had an interface successfully connect to PI but not achieve write access t...
Guest over 3 years ago in PI Interfaces / General 0 No status

Allow scan class 0 to be monitored via Performance Counters

As a PI System Administrator, I would like to monitor the point count and other parameters for scan class 0 via Performance Counters. Currently, this is only exposed via the UniInt Health Tags.
Guest over 3 years ago in PI Interfaces / General 0 No status

Device status tags do not show OPC DA server Invalid client handle errors

When OPC DA interface receives an "Server returned Invalid Client Handle" error, device status tags do not show that error and therefore potential situations where data is not being received by the interface are missed I would be good that device ...
asanzacedo almost 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Stay with RAD View

RAD view is easier to use for troubleshooting.
Guest over 2 years ago in PI Interfaces / General 0 No status

PI interface for OPC DAの配列型タグ対応

PI interface for OPC DAを配列タグ対応にしてほしい。東芝製DCSのデジタルデータの場合、状態を配列型で存在している(例:種別「PB8」、ITEM「LS1」の場合8ビット。種別「PB4」、ITEM「SS1」の場合4ビット)。この値を取得する際、1ビットずつ取得した後にAF演算で1つの値に計算している。対象全タグに対してこの処理を行うことは大変なので、interfaceのところで一度に全ビット取得し、1つの値として取り扱いたい。
kurokuro about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI Interface for OPC DA and VT_ARRAY|VT_BSTR datatype

PI Interface for OPC DA has a plugin called "Time Array" to manage numerical arrays but string arrays are not supported. It would be a good improvement to develop this feature for string arrays.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Enhance OPC server failover capability

Need to trigger failover when a watchdog tag is stale for a configurable duration.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Modifying the functionality of Trend Advise feature for PI OPC interface

As a PI OPC Interface user I would like to get step-like trends whenever that the Trend Advise parameter is enabled (even with having large exception and compression deviations that filter some of the events) so that I don't need to enable the ste...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

debug an arbitrary number of tags belonging to a PI OPC interface instance

It is currently possible to debug one tag, or all tags. Logging timestamp and data for all tags is expensive and make logs harder to read, so one one would like to select an arbitrary number of tags.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 Declined