To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

General

Showing 28

Assure changes made to any configuration of an interface are audit trailed

We noticed that changes to the configuration of newer interfaces / connectors like - PI EMDVBCS interface 4.0 - PI inbatch interface - PI Connector Wonderware Historian are no longer recorded in the PI Audit trail. (see also TechSupport Case # 9...
Carl Van Laer over 2 years ago in PI Interfaces / General 0 No status

Device Status UniInt health tag should update during runtime without needing a status update

Currently, the device status is updated on startup, on change, on shutdown, and on each performance summary interval. However, for a device status tag created while the interface is running in a good state, the device status tag will remain at 'P...
Guest over 2 years ago in PI Interfaces / General 0 No status

Avoid reloading tags after edits of non-key PI Point attributes

Currently, UniInt-based interfaces will reload a tag if edits are detected on any of the PI Point attributes. This is not ideal as edits to non-key attributes (such as EngUnits) will still cause a tag to be reloaded, potentially leading to data so...
Guest over 2 years ago in PI Interfaces / General 0 No status

Support data collection across data diodes or similar technology

Regulatory and/or security requirement to separate data collection from data storage using a one-way data flow. Could apply to Interfaces or Connectors, for example PI Interface for Emerson Ovation. PI Interface/Connector -> one-way data flow -...
Guest over 2 years ago in PI Interfaces / General 0 No status

UNIINT Interfaces and Connectors should be able to retry an output event if output write fails

When an interface fails writing to a DCS system, the interface writes a failure status to the output tag and goes on.  User has requested an option to have an output tag retry after write failure. It would be good to have this functionality i...
jdjohnstn over 2 years ago in PI Interfaces / General 0 No status

Interface / Connector to the SILA Lab Equipment Standard

Hi all,   i got to know this standard: Standards – SiLA Rapid Integration This standard is a really good approach to connect various types of lab equipment. Over it it is possible to fetch for example the RPM of a mixing device, temperature o...
Guest over 2 years ago in PI Interfaces / General 0 No status

Ability to wait successful connection to PI Data Archive and download PI point information during startup

(Posted on behalf of our customer) It can reduce the chance of startup failure because of the connection to PI Data Archive time-out. It's also helpful if interface can reduce time to get PI point information from PI Data Archive.
Guest over 2 years ago in PI Interfaces / General 0 No status

Monthly scans

Allow for monthly scan intervals for scan classes. i.e. "scan monthly on the first hour of the first day of every month".
Guest over 2 years ago in PI Interfaces / General 3 No status

Allowing output point with source tag to keep working even after switching to secondary server

When primary server is down, secondary server is accessed instead of primary server, which is good. However, in the case of output point with source tag, it stops working, then restarting the interface instance of interest is needed. Of course, if...
Toshiro Chiba over 2 years ago in PI Interfaces / General 0 No status

Retire 32-bit versions of PI Interfaces that have a 64-bit version

These days, 32-bit operating systems are used for 1 of 2 reasons: Somebody accidentally installed the 32-bit version instead of the 64-bit version, which is a mistake that OSIsoft has no obligation to accommodate. The computer is very old, in whic...