Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 20 of 5197

Add Mod10 to Custom Data Type Manipulator for Modbus Interface

Please add support for SquareD Mod10 custom datatype to the Modbus Interface. Schneider Electric uses a custom datatype that uses four 16 bit registers. Each register represents an integer. Each integer is then multiplied by a factor and all resu...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Option to hide header row in results from Explore Events function

When pulling in results from searches in the Explore Events function, the option to hide the results header row would be beneficial when working with multiple attribute filter values in the same sheet
Guest almost 3 years ago in AVEVA™ PI DataLink™ / Events (EF) 0 No status

Test Modbus Serial interface with newer Operating Systems

Currently the Modbus Serial interface supports Windows 7 as the latest possible operating system. Please test the Modbus Serial interface version 4.0.7.61 with operating systems such as Windows 10 or 11. Or release a new Modbus Serial interface th...
Rachel Morgenroth about 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Provide support for Modbus function code 20

Provide support for Modbus function code 20
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 No status

Incorporate event frame acknowledgements into the event frame search features

We are now able to acknowledge events via PI Coresight. This information is then stored in the PI AF back end. However, there is currently no way to retrieve this information via PI Datalink. While the EF search panes have a couple of options fo...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Events (EF) 0 Declined

Manual selection of Event Frame

I would like to select Event Frame/ Event Frames from the Preview in Explore Events task-pane and result returns manually selected Event Frame/ Event Frames only.
Willy Seah Wei Liat over 3 years ago in AVEVA™ PI DataLink™ / Events (EF) 0 Declined

Export Attachments or Attachment Path Attached to Event Frame Annotations

We are able to currently see annotations for Event Frames but there is no easy way to quickly get a bulk export of Event Frames with Annotations along with what was attached to it, be it file name or path. It would be good to have another column t...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Events (EF) 0 Declined

POINDexter app be modified such that addresses beyond 64000 can be used

POINDexter application be modified such that addresses beyond 64000 are able to be ‘tested’ / polled, rather than having to configure a tag to read those registers
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 3 No status

Interface for Modbus output to 4byte (32bit) registers

There are Modus supporting devices that feature 32bit single registers (e.g ROC800-Series). PI Interface for Modbus should be updated to have support to output to these 4byte (32bit) registers. Currently PI Interface for Modbus only has support f...
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 2 No status

Support Modbus device failover

Enhance the interface to support redundant Modbus devices with different network cards/IP addresses. The controllers would publish a status update on the active device, and the interface should request data from it accordingly.
Guest over 3 years ago in PI Interfaces / PI Interfaces for Modbus 0 Declined