To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 430 of 5219

Trilinear Interpolation

The ability to utilize three columns as input for interpolation from an AF Lookup Table to determine the result for a fourth column could be beneficial for predictions and analysis. Currently, only linear and bilinear interpolation is possible fr...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Function to extract Data Reference Type

We would like to be able to extract the data reference type (PI Point, None, Formula, Table Lookup, etc.) for an attribute using PI Analysis, similar to the TagType function for PI points.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Improve usability of TagNum function

The TagNum function seems to be the only function that requires a double quote as opposed to single quotes. Many other TagXXX functions call for single quotes for its attribute or PI Point arguments.
Jinmo Yi over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Thorough Analysis service message logs

Having more thorough and detailed messages for the Analysis service in the event logs, especially upon startup. Environment details + Language settings that the Analysis service is using should be mentioned in the startup logs in order to better ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow Analysis timestamp override feature to output milliseconds

When using an analysis variable as the output timestamp, it appears that the actual output timestamp is floored to the nearest second, shaving off any millisecond count. This is not a huge priority on our end, but I wanted to ask in case it was a ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Remove tag need for Exit() and NoOutput() in analysis

Allow analysis outputting to Analysis Data Reference attributes to make use of the functions Exit() and NoOutput(), instead of requiring only PI Point Data Reference attributes.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Enhancement for OPC HDA to add switch  '/outputsnaptime'

OPC HDA Interface would be enhanced to use  switch '/outputsnaptime'.  For output tags, the interface would use the timestamp from the original event that triggered the output to timestamp the data. Note: This was previously Enhancement...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

DNP3: DNP3 XML file, make defaults explicit

Upon initial configuration, the XML config file does not include the default interface settings.  This can cause confusion for the user.  Explicitly add the elements for the default values to the XML config file. Note: This was previous...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 Declined

CSI UCOS Enhancement: Implement Bumpless Download

The new CSI UCOS API now supports a "bumpless download". "CSI has recently added what they call a “bumpless download” feature to their UBrowser application that the interface uses to communicate with the database. What this does is allows the da...
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

Cal ISO: allow instruction level data to use batch level start time

allow instruction level data to use batch level start time. Add an option to allow this. use case: the instruction level start time is the time when the DOT should be ramped up or down.  The batch start time is a few minutes before that times...
Clint Ramsey over 3 years ago in PI Interfaces / Other Interfaces 0 No status