Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 173 of 5192

PI Interface for GE HABConnect FLDTIME Support for COUNT Objects

Currently only POINT/ANALOG fields support COUNT. This request would be to enhance the interface to additionally support the COUNT field.
Guest over 3 years ago in PI Interfaces / Other Interfaces 1 No status

PI Interface for ABB Web Imaging System via ABB CNI

CNI interface should support message 25. Currently, we do not support any message beyond 22.
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

Interface TCP\IP para Data-Logger Davis (WeatherlinkIP)

Se recomienda agregar funcionalidad para adquiquirir datos de un DataLogger WeatherlinkIP, ya que actualmente solo se soporta conexiones seriales con este data Logger: Davis Vantage Pro / Pro Plus Weather Station (NTI) Davis Weather Station (NTI)...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

MV90 interface

We see some value in getting a read/write interface with Itron's MV90 billing system database. Being able to see billing interval billing data in PI would be valuable as well as being able to transfer billing data between other partners via PI to ...
Guest over 3 years ago in PI Interfaces / Other Interfaces 1 No status

AF Attribute not recongized in CONNECT transfer configuration if PI point data reference config string contains a datatype

We encountered an issue with PI to CONNECT (using current version of the Agent 2.2) not recognizing AF Attributes with PI Point Data References which have the pointtype in the data reference configuration. So that means if there is a config string...
Julian Weber over 2 years ago in PI to CONNECT / General 0 No status

Configure PI Interface for Emerson-Ovation to read drop status points Ovation.

knowing in real-time if an ovation server is down and would help with maintaining the PI server.
Betty about 1 year ago in PI Interfaces / Other Interfaces 0 No status

PI Interface for Bacnet: Adding support of ObjectType=Timer

We would like to get a value of ObjectType=Timer object in PI BACNet interface but it is not supported. One of the Timer object contains important time setting and we need to check it every month. However currently we need to check the value from ...
Kenji Hashimoto over 1 year ago in PI Interfaces / Other Interfaces 1 Declined

Use PI Server Alternate Display Name in stream naming pattern

The PI Server Alternate Display Name is only used to build the stream IDs. It would be better to use it in the stream naming pattern as well.
Clement Dekeyser almost 3 years ago in PI to CONNECT / General 0 No status

Seamless change of PI Server Alternate Display Name

When the PI Server Alternate Display Name is modified, new streams are created to receive live data while historical data remains only in the existing streams. It would be better to automate: the deletion of existing streams the backfilling of new...
Clement Dekeyser almost 3 years ago in PI to CONNECT / General 0 No status

More options when searching for PI Points

During a Lighthouse project a customer noted that they have a number of points in their data archive that are no longer on scan. It would be helpful, then, if the PI Point Search facilities in PI to CONNECT allowed use of the ‘scan on/off’ flag so...
Guest about 3 years ago in PI to CONNECT / General 0 No status