Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 99 of 5199

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Lock the time range on a display

It would be helpful in some use cases to be able to lock the time range on displays, so that clicking through the time bar or clicking or touching a trend does not adjust the time range. One particular use case this would be helpful for is when ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Navigation 1 Declined

Custom names for the databases in PI Vision

If there are several AF Servers that have Databases with the same name. In PI Vision these databases show up with the same name and in order to differentiate between them, we need to hover over them with the mouse to see the tooltip which shows t...
Mohammed Al-Shaikh Jafar over 3 years ago in AVEVA™ PI Vision™ / Navigation 0 No status

Start and end date

Please make it possible to use the same date format as in Processbook. F.e. being able to enter "+7d"/"+5m"/"+1mo" etc etc at the end time section instead of being limited to use prefixed options. Make it so as in other PI applications.
Unknown Unknown over 3 years ago in AVEVA™ PI Vision™ / Navigation 2 No status

Change, when opening a display the default should be current time ("Now" button green), not the time selected when saving the display.

No description provided
stim over 3 years ago in AVEVA™ PI Vision™ / Navigation 0 No status

Keyboard Shortcut to toggle between Design and View Mode

Avoid mouse deplacement when by switching in design mode with a keyboard shortcut
GregBo over 3 years ago in AVEVA™ PI Vision™ / Navigation 0 No status

Parameter for restarting the interface if no connection to the OPC server can be established after a defined period of time

We use the Phoenix Contact Firewall with the OPC Inspector. When the OPC server restarts or breaks the connection for a few seconds, the firewall blocks all ports except port 135. After initial connection through this port, new firewall rules are ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status