To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 75 of 5199

Write business data to PI Vision display

To be able to add business data coming from existing business systems into PI Vision displays.
Guest over 3 years ago in AVEVA™ PI Vision™ / Reporting 0 Declined

DCD alarm report

NEXT TO TRACK DCD EVENTS AND RUN A REPORT WEEKLY/ MONTHLY/YEARLY WE ARE TRACKING IN ADMS AND NEED A WAY TO SEND VIA EAMIL. scada point ids Bin 00014-00018 on reclosers. Paul Unrast
Guest over 3 years ago in AVEVA™ PI Vision™ / Reporting 0 No status

Felaktig signal.

PK051 ÖVY signal är felaktig, det är PK042 ÖVY som är inlagd i Översikt Luleälven. Med vänlig hälsning Jerry Rutström
Guest over 3 years ago in AVEVA™ PI Vision™ / Reporting 0 No status

Device status tags do not show OPC DA server Invalid client handle errors

When OPC DA interface receives an "Server returned Invalid Client Handle" error, device status tags do not show that error and therefore potential situations where data is not being received by the interface are missed I would be good that device ...
asanzacedo almost 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI interface for OPC DAの配列型タグ対応

PI interface for OPC DAを配列タグ対応にしてほしい。東芝製DCSのデジタルデータの場合、状態を配列型で存在している(例:種別「PB8」、ITEM「LS1」の場合8ビット。種別「PB4」、ITEM「SS1」の場合4ビット)。この値を取得する際、1ビットずつ取得した後にAF演算で1つの値に計算している。対象全タグに対してこの処理を行うことは大変なので、interfaceのところで一度に全ビット取得し、1つの値として取り扱いたい。
kurokuro about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI Interface for OPC DA and VT_ARRAY|VT_BSTR datatype

PI Interface for OPC DA has a plugin called "Time Array" to manage numerical arrays but string arrays are not supported. It would be a good improvement to develop this feature for string arrays.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Identification / labeling of changed (manually edited) values within reports

For pharmaceutical environment is would be an great option to indicate on displays (e.g. Coresight) whether or not an AF attribute’s value or a PI tag’s archive value has been manually edited. The way of indication dosn't really matter, could be a...
Guest over 3 years ago in AVEVA™ PI Vision™ / Reporting 0 Declined

Enhance OPC server failover capability

Need to trigger failover when a watchdog tag is stale for a configurable duration.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Modifying the functionality of Trend Advise feature for PI OPC interface

As a PI OPC Interface user I would like to get step-like trends whenever that the Trend Advise parameter is enabled (even with having large exception and compression deviations that filter some of the events) so that I don't need to enable the ste...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

debug an arbitrary number of tags belonging to a PI OPC interface instance

It is currently possible to debug one tag, or all tags. Logging timestamp and data for all tags is expensive and make logs harder to read, so one one would like to select an arbitrary number of tags.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 Declined