To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 75 of 5194

In the PI Server install kit, label deprecated components as such and state the replacement

The PI Server install kit includes many deprecated components, namely: PI Totalizer Subsystem PI Alarm Subsystem PI Performance Equation Scheduler PI Batch Subsystem PI Module Database Builder AF Collective Manager Also, the PI AF Link Subsystem i...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Installation 0 No status

Create 2 new client install kits: PI System Client & PI For Excel

Administrators and regular users of PI are mainly concerned with these PI client programs: PI System Management Tools PI System Explorer PI Builder PI DataLink However, the install kits are not beginner-friendly: Many users think that PI DataLink ...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Installation 4 No status

Allow OPC DA  Output Tags to capture OOO events

Currently there is no way to send corrected values to the OPC DA Server since they are triggered by snapshot. It would be useful if there was a way to alter the values that get sent in case there are substituted/replaced values.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Automatic restart of the OPC interface whenever OPC server is restarted

whenever the OPC server undergoes any restarts or configuration changes, the OPC interface will delete all old connections, groups, etc. and it will establish a new connection to the OPC server, loading all ItemID's etc (as if it is an automatic r...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

Have a consistent presence of a terminating \ in the PIHOME and PIHOME64 environment variables

By default, PIHOME is "C:\Program Files (x86)\PIPC" and PIHOME64 is "C:\Program Files\PIPC\". For new installations, please consider either having the terminating \ on both or removing the terminating \ from both. The current inconsistency can con...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Installation 0 No status

Remove PI System Explorer (Legacy 32-bit) from PI AF Client

When PI AF Client is installed, it includes a program called "PI System Explorer (Legacy 32-bit)". Please remove this from PI AF Client. The continued support of 32-bit PI AF SDK makes sense, since 3rd-party programs may still depend on the 32-bit...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Installation 2 No status

The PI Server Installation kit should list the PI software requirements sooner in the install

As a PI System Administrator, I would like the PI Server Installation kit to list out any PI Software that will be included with a selected role or feature before the Summary step so that I can determine what will be installed without having to fi...
Guest over 3 years ago in AVEVA™ PI Server / Installation 0 No status

Support dynamic OPC addresses

My OPC server's items have the OPC server node name included in the itemID, for example: serverA.AB_1234.PV. I have redundant OPC servers and redundant interfaces (in failover) and would like the tags to refer to the correct OPC address including ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Interface should reload performance counters after failover and keep track of them.

The interface should be designed to reload counters both at startup and when becoming the active interface after a failover. The interface should realize the counter is not available and periodically attempt to reload (ideally with a message to th...
Nicolas Capera Choconta over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status