To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 81 of 5194

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OIDC authentication with federated accounts (through CONNECT) requires too many steps

Currently, it is a 5-step process to get authenticated. After the first authentication, it is only a 3-step process, but still clunky.
Laurie Dieffenbach about 1 year ago in AVEVA™ PI Server / Security 0 No status

Change process to release security patches

Hello, whenever Osisoft identifies security issues on PI / PI AF, they deliver fixes through the next release of these applications. This is not convenient as upgrading to a new release is a risk that we don't like to be forced to take and has a ...
Guest over 3 years ago in AVEVA™ PI Server / Security 1 No status

Rename or add descriptions for Read, Write, Read Data, and Write Data permissions in PI System Explorer

In PI System Explorer, the definitions of the Read, Write, Read Data, and Write Data permissions are not clear from their names. Their names are also misleading. For example, Read permission can be interpreted as "General Read", making Read appear...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Security 1 Declined

Allow sorting of Database Security Identities

There should be some type of sorting feature for the Security Identities/Securities listed in the Database Security section of System Management Tools. A simple fix would be to allow us to remove an identity, re-add it and have that appear on the ...
Guest over 3 years ago in AVEVA™ PI Server / Security 0 Declined

Parameter for restarting the interface if no connection to the OPC server can be established after a defined period of time

We use the Phoenix Contact Firewall with the OPC Inspector. When the OPC server restarts or breaks the connection for a few seconds, the firewall blocks all ports except port 135. After initial connection through this port, new firewall rules are ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to the OPC DA Interface so that the user can adjust the maximum advise tag exception delay for Event/Trigger tags

This affect to delay in Event\Trigger points. KCS: Delay in Event Points. When using Event Points, we purposefully do have a delay (if excMax is > 2 s then 2 s else 0.9*excMax) for advise tags (Trigger Point) before they're sent to the PI Serv...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to UniInt so that the user can adjust the minimum wait time for checking for new events from the Update Manager

This affects the delay in Event\Trigger tags. KCS: Delay in Event Points. The largest and most variable delay seems to come from the time the event is written to the PI Server and the time the interface (UniInt) picks, which is between 0ms-1,000m...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA Interface to run on Microsoft Visual C++ 2015-2022

Can only install OPC DA Interface (2.7.2.20) with "Microsoft Visual C++ 2015-2019 Redistributable" installed.
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 1 Planned

Have Platform Common services for PI use least privilege access on the Azure directory

Some Azure Active Directory (Entra ID) administrators will be hesitant to give the registered application for the AIM Server Directory.Read.All privileges. It should be feasible to give the application lesser privileges on the directory while stil...