Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

"Create or Update Data Reference" through OSIsoft.Powershell

It is already possible to create an instance of an existing AF Element Template by using the powershell cmdlet Add-AFElement with the -AFElementTemplate option. The element is then created in the AF tree, however if there are tag creation rules de...
phsutter about 4 years ago in AVEVA™ PI System Access (PSA) / General 0 No status

Support importing multiple aliases using the KST.INI file during setup

As a PI System Admin, I would like to be able to specify multiple aliases for one PI Server in a KST.INI file that will be used to create a predefined set of PI Servers during a silent install of the PI SDK so that I can ensure that all users have...
Guest about 4 years ago in AVEVA™ PI System Access (PSA) / General 0 No status

PItoPI should switch from COLD to WARM failover instead of exiting

As of version 3.8.1 COLD failover is no longer supported by the PI to PI Interface (https://techsupport.osisoft.com/Troubleshooting/Enhancements/19255OSI8). However, older versions supported COLD failover. In the case of upgrading the interfaces, ...
Guest about 4 years ago in PI Interfaces / PI to PI Interface 2 No status

Support dynamic OPC addresses

My OPC server's items have the OPC server node name included in the itemID, for example: serverA.AB_1234.PV. I have redundant OPC servers and redundant interfaces (in failover) and would like the tags to refer to the correct OPC address including ...
Guest about 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest about 4 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add the Ability to Control the Time Period for Backfilling Publication Data

As a PI Cloud Connect user, I would like to be able to control the time period over which data is backfilled when I subscribe to a publication that has previously published data, so that I don't need to grab data over the entire time range if I do...
Guest about 4 years ago in PI Cloud Connect 1 No status

PI Interface for OPC DA bitmask plugin with float data type

PI Interface for OPC DA has a plugin called "Bitmask" to extract specific bits from regular OPC values that are of type Int (i.e VT_I2 / VT_I4 / VT_UI2) but other data types such as floats are not supported. It would be good to have Float data typ...
Guest almost 2 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Interface should reload performance counters after failover and keep track of them.

The interface should be designed to reload counters both at startup and when becoming the active interface after a failover. The interface should realize the counter is not available and periodically attempt to reload (ideally with a message to th...
Nicolas Capera Choconta about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Search ability in AF Client on more than just element.

It would be nice to be able to search anything when it comes to AF Client. If I wanted to search and find reference to all Motor Speed Attributes.If I wanted to search on where a tag 'Sinusoid' for example was referenced in:Attributes, Analysis', ...
BrentWebsterADM about 3 years ago in AVEVA™ PI System Access (PSA) / General 0 No status

Support DST Transition on Second Granularity in PI SDK

A user tries to retrieve date with timestamp 03-Nov-2018 23:59:59 (1 second before Daylight Saving Time beginning) in PI SMT, but the returned event has a timestamp of 04-Nov-2018 00:59:59. This is because PISDK timezone design is such that it can...
Guest about 4 years ago in AVEVA™ PI System Access (PSA) / General 0 Declined