To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 51 of 5194

Support dynamic OPC addresses

My OPC server's items have the OPC server node name included in the itemID, for example: serverA.AB_1234.PV. I have redundant OPC servers and redundant interfaces (in failover) and would like the tags to refer to the correct OPC address including ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Interface should reload performance counters after failover and keep track of them.

The interface should be designed to reload counters both at startup and when becoming the active interface after a failover. The interface should realize the counter is not available and periodically attempt to reload (ideally with a message to th...
Nicolas Capera Choconta over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Cygnet - Check for prerequisites during the installation process instead of in the logs on startup

Currently, if some Cygnet prerequisites are missing, the following error is logged: Although the errors are clear, this verification step should also occur during the initial installation process. Please review the "Installation requirements for...
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Cygnet connector should not update old archives unless being backfilled

No description provided
Guest over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Capability to disable a data source within connector configuration

No description provided
Guest over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Allow PI Connector for Cygnet to support a mix of VHS and CVS when Automatic UDC Recognition is enabled

With Automatic UDC recognition enabled, PI Connector for Cygnet defaults to placing all UDC's in the CVS column by default, or in the VHS column if "Prefer VHS for Automatic UDC recognition" is checked. This behavior should be a preference, not a...
Guest over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status