To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 94 of 5197

The MQTT Connector should be able to connect to MQTT Brokers that requires Client SSL Certificate.

Currently the MQTT Connector only supports username/password authentication. This is great for local brokers/servers, but very unpractical when connecting to cloud brokers like AWS IoT Core. Adding support for Client SSL authentication will make i...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI Connector for MQTT Sparkplug - Allow users to configure clean session flag

I would like to be able to configure the 'clean session' flag when configuring data sources on the connector, to allow for messages to be buffered on the broker in the event that the connector is unavailable. Currently the connector sets the clea...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

PI APS Connector for GE XA21

The PI APS Connector for GE XA21 can not handle digital sets from GE XA21. This makes the Automatic Point Sync only semi automatic, You need to load the digital sets maually while Points are updated automatically. If the APS can transfer digital s...
ErikJansson over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

IEC61850 - Ability to connect to a non-default port

The connector is currently unable to connect and collect data from MMS Servers using a port other than the default 102.Port selection should be part of the data source configuration
Gabriel Verreault over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Enable the option to not sync/overwrite pi point attributes for PI Connector GE e-terrahabitat after connector is started

As of version 1.1.1.42, by specifing tag under a given field node, this allows you to set any PI point attribute you want with an associated value. Furthermore, you can specify an associated key filter for that attribute. However, if we manually ...
Ee Sheing Lee over 3 years ago in PI Connectors / Other specific PI Connector 3 Declined