Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 74 of 5199

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI Adapter for Structured Data Files support for UoMs

No description provided
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files / General 6 Tell us more

Include [optional] unit of measure in the data selection configuration.

Some data sources do not provide a unit of measure. It would be useful to be able to specify the unit of measure as part of the data configuration so that this information is provided to EDS/PI/ADH through the data flow.
Mike Horrocks almost 2 years ago in AVEVA™ Adapters / General 1 No status

host adapter(s) as a service

SaaS solution for customers with benefits thereof.
Guest almost 2 years ago in AVEVA™ Adapters / General 1 No status

Parameter for restarting the interface if no connection to the OPC server can be established after a defined period of time

We use the Phoenix Contact Firewall with the OPC Inspector. When the OPC server restarts or breaks the connection for a few seconds, the firewall blocks all ports except port 135. After initial connection through this port, new firewall rules are ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to the OPC DA Interface so that the user can adjust the maximum advise tag exception delay for Event/Trigger tags

This affect to delay in Event\Trigger points. KCS: Delay in Event Points. When using Event Points, we purposefully do have a delay (if excMax is > 2 s then 2 s else 0.9*excMax) for advise tags (Trigger Point) before they're sent to the PI Serv...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to UniInt so that the user can adjust the minimum wait time for checking for new events from the Update Manager

This affects the delay in Event\Trigger tags. KCS: Delay in Event Points. The largest and most variable delay seems to come from the time the event is written to the PI Server and the time the interface (UniInt) picks, which is between 0ms-1,000m...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA Interface to run on Microsoft Visual C++ 2015-2022

Can only install OPC DA Interface (2.7.2.20) with "Microsoft Visual C++ 2015-2019 Redistributable" installed.
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 1 Planned

Any Patches/Updates needed to be ready for Microsoft's DCOM hardening in 2023?

By March 2023 Microsoft will enforce a patch that upgrades DCOM security. Some applications that use DCOM (such as the PI OPC interface) will require some updates to continue to work. Are there any updates that I need to apply on any of the PI com...
James_Podobea about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status