To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 326 of 5193

Scheduled Update Data for Business Integrator

We would like the ability to "schedule" a reoccurring "update data" write for a PI View. We have several scheduled backfills for processes where data is somewhat delayed (i.e. lab data) but to get the data in the PI View today we need to do a manu...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Fix the 'Sort by Date' functions on the UI to sort as datetime rather than string

currently when we try to get the columns sorted, the dates are sorted as strings and not actually by date. This makes administration tedious.
Kareema Ramli 9 months ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Interface should reload performance counters after failover and keep track of them.

The interface should be designed to reload counters both at startup and when becoming the active interface after a failover. The interface should realize the counter is not available and periodically attempt to reload (ideally with a message to th...
Nicolas Capera Choconta about 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Set the default installation path to PIHOME64 instead of C:\Program Files\OSIsoft\Integrators\Esri ArcGIS\

The installation path should be consistent with all other OSIsoft products that are installed in PIHOME64.
Gabriel Verreault over 3 years ago in PI Integrators / PI Integrator for Esri ArcGIS 1 No status

Support ArcGIS Map Services

As a PI Integrator for Esri ArcGIS user, I would like the PI Integrator to be able to publish Map Services (in addition to Feature Services) so that it can integrate with my Esri application that is not able to display Feature Services.
Guest over 3 years ago in PI Integrators / PI Integrator for Esri ArcGIS 0 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Use /opcstopstat when both interfaces in failover pair are shut down

We would like to have some sort of digital state such as "Intf Shut" written to all OPC tags when both interfaces in a failover pair are shut down. Currently, the /opcstopstat and /stopstat parameters (which write a specified state to all tags wh...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status